UNIVERGE SV8100
Issue 1.0
System Maintenance Manual
3 - 15
This table shows all extensions that are registered to the SV8100 – not those
that are currently connected.
R
ip info 5
This table shows H.323 trunk registrations. An entry for each H.323 endpoint will
be listed, along with the IP address and E.164 (telephone number) assignment.
SV8100 Net IP destinations are not listed.
########## IP Phone Table ##########
--DtermIP-------------------------------------------
Extension Number = 3203
SerialPort = 257
IP Address 192.168.1.131
Voice Path Port=4000
CALL SIG Port=3458
Terminal Type=2
--------------------------------------------
--DtermIP-------------------------------
Extension Number = 3232
SerialPort = 258
IP Address 192.168.100.200
Voice Path Port=4000
CALL SIG Port=3458
Terminal Type=2
--------------------------------------------
--DtermIP-------------------------------
Extension Number = 3290
SerialPort = 266
IP Address 192.168.102.200
Voice Path Port=4000
CALL SIG Port=3458
Terminal Type=2
-------------------------------------------
--H.323---------------------------------
Extension Number = 3291
SerialPort = 270
IP Address 192.168.1.193
RAS Port=56782
Call SIG Port=1720
Terminal Type=1
----------------------------------------
Total = 4 IP Terminals
####################################
Example:
##### IP Inter-Connection TABLE #####
--1 system-- Registered
SYSTEM IP: 192.168.1.20
E164 ADDR:1
E164 Len :1
Total : 1 system
##################################
Содержание Univerge SV8100
Страница 2: ......
Страница 3: ...System Maintenance Manual INT 2057 UNIV ISSUE 1 0...
Страница 4: ......
Страница 6: ......
Страница 8: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 18: ...Issue 1 0 UNIVERGE SV8100 1 6 Troubleshooting IP on an SV8100 System Figure 1 3 Trace File Example...
Страница 40: ...Issue 1 0 UNIVERGE SV8100 2 22 System Maintenance NOTES...
Страница 76: ...Issue 1 0 UNIVERGE SV8100 3 36 NOTES...
Страница 77: ......
Страница 78: ...System Maintenance Manual NEC Unified Solutions Inc Issue 1 0...