Program
47
Item No.
Item
Input Data
Default
07
Digital Pager Callback Number
(Pager CBack)
Use this option to set the Digital Pager Callback
Number portion of the Message Notification callout
number for a digital pager. This is the portion of the
callout number that is appended to the pager
service telephone number. Normally, this option
should be
X
*
M#
, where:
•
X
is the number of the extension that gener-
ated the notification.
•
*
is a visual delimiter (to make the pager
display easier to read).
•
M
is the number of new messages in the
extension mailbox.
•
#
is the digit normally used by the pager
service for positive disconnect.
Digits
(12 maximum, using 0~9,
#
and
*
)
M
(Number of messages -
entered by pressing
LK1
)
X
(Extension number - entered
by pressing
LK2
)
InMail automatically replaces the
X command with the number of
the extension that initially
received the message.
X
*
M
#
08
Delay in Dialing Digital Pager Callback Number
(Pager Dial Delay)
Use this option to set the delay (0~99 seconds)
that occurs just before InMail dials the Digital
Pager Callback Number portion of the Message
Notification callout number for a digital pager. Set
this delay so the pager service has enough time to
connect to the digital pager before sending the
callback number. Your pager service may be able
to help you determine the best value for this option
(0~99 seconds). By default, this option is 9
seconds. When placing a digital pager notification,
the system: Seizes the trunk specified. Dials the
user-entered notification number (in
Message
+
OP
+
N
).
Waits the
47-01-08: Delay in Dialing Digital
Pager Callback Number
interval.
Dials the number entered in
47-01-07: Digital
Pager Callback Number
.
The system assumes that the notification number
completes dialing approximately 4 seconds after
trunk seizure. This means that, by default, the
Digital Pager Callback Number is dialed into the
pager service about 13 seconds after trunk
seizure.
0~99 (sec)
30
09
Wait Between Digital Pager Callout Attempts
(Notify Pager Intvl)
Use this option to set the minimum time (1~255
minutes) between unacknowledged or unanswered
digital pager Message Notification callouts. (A
subscriber acknowledges a digital pager notifica-
tion by logging onto their mailbox.) After this time
expires, InMail tries the callout again (for up to the
number of times set in
47-01-14: Number of
Callout Attempts
).
If the system dials the callout number and the
pager service is busy, it retries the number in one
minute.
1~255 (min)
15
10
Wait Between Non-Pager Callout Attempts
(Notify N-Pgr Intvl)
Use this option to set the minimum time (1~255
minutes) between non-pager Message Notification
callouts in which the destination answers, says
Hello, dials 1 to acknowledge and then enters the
wrong security code.
1~255 (min)
20
11
Wait Between Busy Non-Pager Callout At-
tempts
(Notify Busy Intvl)
Use this option to set how long InMail waits (1~255
minutes) after it dials a busy non-pager callout
destination, before retrying the callout number.
1~255 (min)
15
Issue 0.1
SL1000
Programming Manual
2-355
Содержание SL1000
Страница 1: ...SL1000 Programming Manual A50 031167 001 ISSUE 0 1 ...
Страница 12: ......
Страница 20: ......
Страница 30: ...Program 10 Feature Cross Reference Universal Slots Issue 0 1 SL1000 Program 10 System Configuration Setup 2 10 ...
Страница 43: ...Program 10 Feature Cross Reference Voice Over Internet Protocol VoIP Issue 0 1 SL1000 Programming Manual 2 23 ...
Страница 84: ...Program 11 Feature Cross Reference Hotel Motel Issue 0 1 SL1000 Program 11 System Numbering 2 64 ...
Страница 114: ...Program 14 Feature Cross Reference None Issue 0 1 SL1000 Program 14 Trunk Basic Setup 2 94 ...
Страница 179: ...Program 20 Feature Cross Reference Class of Service Issue 0 1 SL1000 Programming Manual 2 159 ...
Страница 276: ...Program 24 Feature Cross Reference Call Forwarding Off Premise Issue 0 1 SL1000 Program 24 Hold Transfer Setup 2 256 ...
Страница 295: ...Program 26 Feature Cross Reference Automatic Route Selection ARS Issue 0 1 SL1000 Programming Manual 2 275 ...
Страница 377: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Programming Manual 2 357 ...
Страница 386: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 366 ...
Страница 396: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 376 ...
Страница 545: ...Program 90 Conditions None Feature Cross Reference Maintenance UserPro Issue 0 1 SL1000 Programming Manual 2 525 ...
Страница 578: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Страница 579: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Страница 580: ...SL1000 Programming Manual NEC Corporation Issue 0 1 ...