Program
34
Program 34 : Tie Line Setup
34-11 : E1 Trunk Basic Setup
Level
IN
Description
Use
Program 34-11 : E1 Trunk Basic Setup
to define the basic setting of each E1 Trunk.
Input Data
Trunk Port Number
1~126
Item No.
Name
Input Data
Default
01
E1 Trunk Type
Use this option to specify the
E1Signal type(0-8). Set this option for
compatibility with the connected
telco.
0 = Standard Trunk
1 = Argentine Pulsed Clear Back Trunk
2 = Argentine Pulsed Answer Trunk
3 = Brazil With seizure acknowledge Trunk
4 = Brazil Without seizure acknowledge Trunk
5 = Brazil E&M Signal A(Idle=0) Trunk
6 = Brazil E&M Signal A(Idle=1) Trunk
7 = Brazil E&M Signal B(Idle=0) Trunk
8 = Brazil Code for collect call blocking Trunk
0
02
MFC Dialing Type
Use this option to specify the MFC
Dialing Type. The following table
shows the available MFC Dialing
Type choices, By default, this option
is 0 (MFC Dialing not used).
0 = MFC Dialing not used
1 = NEC Standard
2 = Argentina
3 = Brazil
4 = Chile
5 = Colombia
6 = Mexico
7 = Venezuela
0
03
MFC Group B
Use this option to enable(1) or
disable(0) the MFC Dialing Group B
supervisory signaling. Since not all
central offices provide Group B
signaling, set this option for compat-
ibility with the connected telco. By
default, this option is Disable(0).
0 = Disable
1 = Enable
0
04
Expected Number of MFC Digits
Use this option to specify the number
of digits in the ANI number. This is
required for ANI since delimiters do
not mark the beginning and end of
the data string. The system must
know how many digits of incoming
ANI Caller ID data to interpret.
0~20
7
Conditions
After set PRG34-11-01, the E1 card needs resets.
Feature Cross Reference
• E1 Trunking
Issue 0.1
SL1000
Programming Manual
2-319
Содержание SL1000
Страница 1: ...SL1000 Programming Manual A50 031167 001 ISSUE 0 1 ...
Страница 12: ......
Страница 20: ......
Страница 30: ...Program 10 Feature Cross Reference Universal Slots Issue 0 1 SL1000 Program 10 System Configuration Setup 2 10 ...
Страница 43: ...Program 10 Feature Cross Reference Voice Over Internet Protocol VoIP Issue 0 1 SL1000 Programming Manual 2 23 ...
Страница 84: ...Program 11 Feature Cross Reference Hotel Motel Issue 0 1 SL1000 Program 11 System Numbering 2 64 ...
Страница 114: ...Program 14 Feature Cross Reference None Issue 0 1 SL1000 Program 14 Trunk Basic Setup 2 94 ...
Страница 179: ...Program 20 Feature Cross Reference Class of Service Issue 0 1 SL1000 Programming Manual 2 159 ...
Страница 276: ...Program 24 Feature Cross Reference Call Forwarding Off Premise Issue 0 1 SL1000 Program 24 Hold Transfer Setup 2 256 ...
Страница 295: ...Program 26 Feature Cross Reference Automatic Route Selection ARS Issue 0 1 SL1000 Programming Manual 2 275 ...
Страница 377: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Programming Manual 2 357 ...
Страница 386: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 366 ...
Страница 396: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 376 ...
Страница 545: ...Program 90 Conditions None Feature Cross Reference Maintenance UserPro Issue 0 1 SL1000 Programming Manual 2 525 ...
Страница 578: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Страница 579: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Страница 580: ...SL1000 Programming Manual NEC Corporation Issue 0 1 ...