CHAPTER 20 ELECTRICAL SPECIFICATIONS
User's Manual U14826EJ5V0UD
192
Power-on-Clear Circuit Characteristics
(1) POC
(a) DC characteristics (T
A
= –40 to +85
°
C,
V
DD
= 1.8 to 5.5 V (
µ
PD789860, 789860(A), 78E9860A), V
DD
= 1.8 to 3.6 V (
µ
PD789861, 78E9861A))
Parameter Symbol
Conditions
MIN.
TYP.
MAX.
Unit
Detection voltage
V
POC
Response
time
Note 1
: 2 ms
1.8
Note 2
1.9
Note 2
2.0
V
Notes 1.
Time from detecting voltage until output reverses and time until stable operation after transition from
halted state to operating state.
2.
Note that the POC detection voltage may be lower than the operating voltage range of these products.
(b) AC characteristics (T
A
= –40 to +85
°
C)
Parameter Symbol
Conditions
MIN.
TYP.
MAX.
Unit
T
Pth1
POC selector used
V
DD
: 0
→
1.8 V
0.01
100
ms
T
Pth2
POC normal operation
V
DD
: 0
→
1.8 V
0.01
100
ms
Power rise time
T
Pth3
POC normal operation
V
DD
: 0
→
1.8 V
T
A
= +25
°
C
10
µ
s
(2) LVI
(a) DC characteristics (T
A
= –40 to +85
°
C,
V
DD
= 1.8 to 5.5 V (
µ
PD789860, 789860(A), 78E9860A), V
DD
= 1.8 to 3.6 V (
µ
PD789861, 78E9861A))
Parameter Symbol
Conditions
MIN.
TYP.
MAX.
Unit
LVI7 detection voltage
V
LVI7
Response
time
Note 1
: 2 ms
2.4
2.6
2.8
V
LVI6 detection voltage
V
LVI6
Response
time
Note 1
: 2 ms
Note 2
V
LVI5 detection voltage
V
LVI5
Response
time
Note 1
: 2 ms
Note 2
V
LVI4 detection voltage
V
LVI4
Response
time
Note 1
: 2 ms
Note 2
V
LVI3 detection voltage
V
LVI3
Response
time
Note 1
: 2 ms
Note 2
V
LVI2 detection voltage
V
LVI2
Response
time
Note 1
: 2 ms
Note 2
V
LVI1 detection voltage
V
LVI1
Response
time
Note 1
: 2 ms
Note 2
V
LVI0 detection voltage
V
LVI0
Response
time
Note 1
: 2 ms
Note 3
2.0 2.2 V
Notes 1.
Time from detecting voltage until output reverses and time until stable operation after transition from
halted state to operating state
2.
Relative relationship: V
LVI7
> V
LVI6
> V
LVI5
> V
LVI4
> V
LVI3
> V
LVI2
> V
LVI1
> V
LVI0
3.
V
POC
< V
LVI0
Содержание PD789860