CHAPTER 9 8-BIT TIMERS 30 AND 40
User’s Manual U14826EJ5V0UD
97
Figure 9-12. Timing of Interval Timer Operation with 8-Bit Resolution
(When CRn0 Changes from N to M (N
>
M))
Count clock
CRn0
TCEn0
INTTMn0
TMO
Note
TMn0
00H
00H
00H
N
−
1
N
M
N
M
N
M
00H
FFH
M
H
Clear
Clear
Clear
TMn0 overflows
because M < N
CRn0 overwritten
Note
Timer 40 only
Remark
n = 3, 4