4
6. Using On-Screen Menu
Menu Descriptions & Functions [RESET]
Returning to Factory Default
The Reset feature allows you to change adjustments and settings to the factory preset for sources by the following
methods:
[CURRENT SIGNAL]
Resets the adjustments for the current signal to the factory preset levels.
All the items in [ADJUST] can be reset.
[ALL DATA]
Reset all the adjustments and settings for all the signals to the factory preset except [ENTRY LIST], [LANGUAGE],
[BACKGROUND], [FILTER MESSAGE], [MULTI-SCREEN COMP.], [SECURITY SETTINGS], [NETWORK SET-
TINGS], [COMMUNICATION SPEED], [STANDBY MODE], [CONTROL ID], [FAN MODE], [DATE, TIME PRE-
SET], [LAMP LIFE REMAINING], [LAMP HOURS USED] and [FILTER HOURS USED].
[ALL DATA (INCLUDING ENTRY LIST)]
Reset all the adjustments and settings for all the signals to the factory preset except [LANGUAGE], [BACK-
GROUND], [FILTER MESSAGE], [MULTI-SCREEN COMP.], [SECURITY SETTINGS], [NETWORK SETTINGS],
[COMMUNICATION SPEED], [STANDBY MODE], [CONTROL ID], [FAN MODE], [DATE, TIME PRESET], [LAMP
LIFE REMAINING], [LAMP HOURS USED] and [FILTER HOURS USED].
Also deletes all the signals in the [ENTRY LIST] and returns to the factory preset.
NOTE: Locked signals in Entry List cannot be reset.
Clearing Lamp hour meter [CLEAR LAmp hOURS]
Resets the lamp clock back to zero.
NOTE: Elapsed time of the lamp use will not be affected even when [RESET] is done from the menu.
NOTE: The projector will turn off and go into standby mode when you continue to use the projector for another 100 hours after the
lamp has reached the end of its life. In this condition you cannot clear the lamp hour meter on the menu. If this happens, press the
HELP button on the remote control for 10 seconds to reset the lamp clock back to zero. Do this only after replacing the lamp.
Resetting the Filter Usage hours [CLEAR FILTER hOURS]
Resets the filter usage back to zero.
NOTE: Elapsed time of the filter use will not be affected even when [RESET] is done from the menu.