Appendix C Use of the Maintenance PC
1. Initialization by the Maintenance PC
NOTES:
The Maintenance PC is also described as NEC Storage
Navigation.
If you operate the maintenance PC for an operation which is
not described in this manual, the disk array unit may
malfunction. Be careful when you operate the maintenance
PC.
1.1 Connection
of Maintenance PC
1.
To connect a PC to the disk array unit, the PC must include the 100/10Base interface and
Internet Explorer Version 5.0 or higher.
2.
Connect the PC to the disk array unit in the one-to-one mode. Connection via a hub may be
possible. However, because the IP address and subnet mask are fixed, the connection to such
an environment as a LAN may cause a malfunction to occur. Use shielded cables for the
connection.
3.
Set the PC on network 10.1.0.xxx/255.255.255.0. (xxx: Decimal number 1-254 except for
10/11)
For the setting, use the Internet protocol (TCP/IP). Remove proxy setting if set.
4.
Use the MNT port for the connection (the left Ether port at the lower left corner on the rear of
the Disk Array Unit). (The right Ether port is used by the WebSAM NEC Storage Manager.)