C-5
1.2.2
FC Port Configuration
Select "4. Configuration"
→
"5. FC Port Configuration" to set the following items.
Set the Target ID Configuration of individual specification.
Port Indicates
port
positions.
Link Attach
Specify link topology. (Select a proper value from the pull-down menu.)
0: FC-AL or Fabric
2: Only FC-AL
3: Only Fabric
Select "2" or "3".
Mode
Indicates the bit meaning on the screen (with a hexadecimal number). The
following two modes can be set currently. Set either one.
Host Director Port
: 0000
Replication Director Port : 0040
Switch
Provide setting for Switch.
See Table 1.2.2 for the rule on loop ID assignment.
See Table 1.2.1 for the relation between the switch setting value and AL_PA.
Data Rate
Set the data rate of the FC link. (Select a proper value from the pull-down
menu.)
0: Auto Negotiate
8: 1Gbps
9: 2Gbps
A: 4Gbps
F: Undecided
Select "8", "9" or "A".
AL_PA Indicates
AL_PA.