CHAPTER 3 SYSTEM DATA PROGRAMMING
– 181 –
ND-71503(E) Rev.5.0
9pch3001.fm
DESCRIPTION
DATA
Specify the PAD data between location groups
to each location number assigned by CM12
Y=39, 50/CM8A Y=5000-5255/CM0A Y=09.
[Series 3200 R6.2 software required]
NOTE 1:
When setting the PAD data for gain-
ing to high value, the echo and
howling may occur.
NOTE 2:
This data setting is valid to the
group that is set to “XX” in the first
data.
•
(1)
(2)
Y=02
XXZZ
XX: 00-63: Location No. of group
ZZ : 00-63: Location No. of group
TTRR
TT (Transmit): 00 -08, 81-88
RR (Receive) : 00 -08, 81-88
NOTE 1
: See below.
2nd Data
PAD Data [dB]
00
0 dB
01/81
+2 dB/–2 dB
02/82
+4 dB/–4 dB
03/83
+6 dB/–6 dB
04/84
+8 dB/–8 dB
05/85
+10 dB/–10 dB
06/86
+12 dB/–12 dB
07/87
+14 dB/–14 dB
08/88
+16 dB/–16 dB
+: Gain
–
: Loss
NOTE 3:
When this data is set to the location number assigned by CM0A Y=09, there are conditions
as follows.
• When using the PN-16VCTA-A card, the PAD data setting both of “Transmit” and “Re-
ceive” is valid, but when using PN-16VCTA card, only the PAD data setting of “Re-
ceive” is valid.
• When using no 16VCT card, the PAD data for “Transmit” and “Receive” cannot be set
to the gain direction.
• The data setting of CM0A Y=23, 24 (PAD level of IP-PAD) is overwritten by this data.
• When using the PN-8IPLA (IP-PAD) card, set the second data in the range of 00-07 (0
dB to
+
14 dB)/81-87 (-2 dB to -14 dB).