CHAPTER 3 SYSTEM DATA PROGRAMMING
– 173 –
ND-71503(E) Rev.5.0
9pch3001.fm
Sample Programming of Alternate Routing
[Series 3200 R6.2 software required]
In the following network configuration, sample programming of each office A, B, and C to office E is
shown below.
In the following network, the terminated call via the private line between office A and office B cannot
make a detour through the private line.
Sample Programming of Office C
Data
Meaning
CM20 Y=0>5: A129
Access code for LCR Group (3)
CM8A Y=A000>3: 4000
Area Code Development Pattern No. (0)
CM8A Y=4000>5: 0005
Route Pattern No. (005) for the Area Code Development Pattern No.
CM8A Y=0005>1: 00520
Order of LCR selection (1: 1st) for the Route Pattern No.
CM8A Y=0005>2: 00120
Order of LCR selection (2: 2nd) for the Route Pattern No.
CM8A Y=5001>167: 001
Destination IP Address Pattern No. (001) for the LCR Pattern No.
CM8A Y=5001>168: 00001
DPC of Office A (00001)
CM8A Y=5005>167: 005
Destination IP Address Pattern No. (005) for the LCR Pattern No.
CM8A Y=5005>168: 00005
DPC of Office E (00005)
CM5B Y=01>00100:
aaabbbcccddd
IP Address of Office A
CM5B Y=01> 00500:
aaabbbcccddd
IP Address of Office E
CM35 Y=186>20: 0
Providing Alternate Routing for the Trunk Route of Virtual IPT (20)
CM35 Y=192>20:0
Providing Alternate Routing for the Trunk Route of IN-side trunk (20)
Private Line
PSTN/
GSTN
PSTN/
Office A
Office B
IP Network
Office C
Office D
Office E
Office F
(1)
(2)
(1)
(2)
(1)
(2)
GSTN
RT=00
RT=00
RT=10
RT=10
RT=20
RT=20
RT=20
2xx
PC=1
PC=2
PC=3
PC=4
PC=5
PC=6
6xx
5xx
4xx
3xx
1xx
JANUARY/31/2003
CCIS VIRTUAL IPT DATA ASSIGNMENT
CÔNG TY VIỄN THÔNG VIỆT PRO
Chuyên phân phối tổng đài NEC
http://vietpro.com.vn