CHAPTER 3 SYSTEM DATA PROGRAMMING
– 175 –
ND-71503(E) Rev.5.0
9pch3001.fm
• When the offices connected by CCIS via Virtual IPT are disconnected due to a fault occurrence, the
link down can be notified to the D
term
s/D
term
IPs that are connected to the offices.
To provide the link down notice with the D
term
s/D
term
IPs, assign the following data.
[Series 3200 R6.2 software required]
DESCRIPTION
DATA
Assign the Event Occurrence Notice button to
the D
term
/D
term
IP.
NOTE:
Assign this data only to the station
number of D
term
/D
term
IP that the
link down is notified.
•
(1)
(2)
Y=00
My Line No. +
+ Key No.
F1364-F1399: Event Occurrence Notice
button No. 01-36
NONE
: No data
Assign the link down notice for CCIS to the
Event Occurrence Notice button.
•
(1)
(2)
Y=0
XX ZZ
XX: 01-36: Event Occurrence Notice but-
ton No.
ZZ: 00: Link Down Notice for CCIS
0 : To notify
1 : Not notified
START
CM90
,
CM9B
END
JANUARY/31/2003
CCIS VIRTUAL IPT DATA ASSIGNMENT
CÔNG TY VIỄN THÔNG VIỆT PRO
Chuyên phân phối tổng đài NEC
http://vietpro.com.vn