CHAPTER 3 SYSTEM DATA PROGRAMMING
– 155 –
ND-71503(E) Rev.5.0
9pch3001.fm
DESCRIPTION
DATA
Specify the threshold of Smooth PAD (limit
function of voice level) to each destination
trunk/terminal via TDSW (characteristic lev-
el).
[Series 3300 software required]
•
(1)
(2)
Y=74
XX ZZ
XX: 00-31: LAN Interface No.
99: All of the LAN Interface No.
ZZ : 00-07, 10-17:Characteristic level No.
0-7, 10-17 (See the table
below)
00 : Smooth PAD OFF
01 : -8 dBm
02 : -5 dBm
03 : -2 dBm
NONE : See the initial data in the table
below.
NOTE:
Follow the initial data settings usually.
I
CM0A
IP-PAD INITIAL
Level
Destination Terminal/Trunk (via TDSW)
Initial Data
PN-8IPLA
PN-32IPLA/
PN-32IPLA-A
7
COT/LDT/DIT/ODT
-5 dBm
Not available
6
Single line telephone (including LLC connection)
-2 dBm
5
PRT/BRT
4
DTI
3
PS
2
D
term
/AD-8/Paging equipment/ATTCON (SN708/
709/712/741) /SN716 DESKCON
1
External BGM source/CFT/DAT
0
IPT
10-17
Fixed allocation to specific Trunk Route/Service Re-
striction Class
J
JANUARY/16/2004