6-4
Issue 2 December 1995
Administering the INTUITY System for the NEAX Integration
Table 6-1.
Switch Link Administration Screen Entries
Field
Description
Data link test
number
Indicates the test number sent to the switch to verify
whether the switch is active.
Setting: A 7- or 10-digit number that is
not
an in-
service extension number. The number of digits must
agree with the setting for the dialstring size set on the
SID. Refer to Chapter 3, "Switch Integration Planning",
to find the dialstring size.
Serial port
Indicates which port on the multi-port circuit card in the
INTUITY system is connected to the integration device.
Setting: Press
(F2) to choose from a menu of
available ports. Settings are in the format /dev/ttysa
x,
where
x
is a letter a - h representing a port on the
circuit card (from right to left). AT&T recommends that
you use /dev/ttysaa as the serial port.
Baud rate
Indicates the rate at which the SID and the INTUITY
system communicate.
Setting: A baud rate of 1200, 2400, 4800, or 9600.
Press
(F2) to choose from a menu of possible
settings. This setting must agree the BAUD setting on
the SID. AT&T recommends that you use a baud rate
of 2400.
Comment
Use the field to enter a comment. Enter a maximum of
30 characters. In your comment, do not use double
quotation marks (“) or
+ backslash (\).
CHOICES
CHOICES
SHIFT
Содержание NEAX 2400
Страница 2: ...Blank Page ...
Страница 8: ...Contents viii Issue 2 December 1995 ...
Страница 36: ...2 10 Issue 2 December 1995 Switch Integration Device Basics ...
Страница 42: ...3 6 Issue 2 December 1995 Switch Integration Planning ...
Страница 52: ...4 10 Issue 2 December 1995 Hardware Installation ...
Страница 70: ...6 10 Issue 2 December 1995 Administering the INTUITY System for the NEAX Integration ...
Страница 104: ...8 16 Issue 2 December 1995 Switch Integration Device Administration ...
Страница 122: ...A 10 Issue 2 December 1995 ...
Страница 128: ...B 6 Issue 2 December 1995 ...
Страница 140: ...Abbreviations ABB 6 Issue 2 December 1995 ...