49
Setting Up Your Projector
• C2 connection
AC power is provided to the projector power supply and the light power supply by separate cables.
AC power supply cable
AC power supply
cable
Electric outlet
Input Selection
C2 connection
Projector
(Main unit)
Light power
supply unit
AC power supply
equipment
AC power supply
equipment
Breaker
Breaker
AC power supply equipment
Do not connect AC power supply voltages to the projector other than those indicated below.
When using with a C1 connection
• 200 - 240 V AC, single phase, 50/60 Hz
When using with a C2 connection
• 200 - 240 V AC, single phase, 50/60 Hz (projector power supply)
• 200 - 240 V AC, single phase, 50/60 Hz (light power supply)
Breakers
When connecting the AC power supply from the power supply equipment of the building to the projector, be sure to connect
it through a breaker. The capacity of the breaker must be as indicated below.
When using with a C1 connection
• Power supply for pro power supply for light
200 - 240 V AC: 40A
When using with a C2 connection
• Power supply for projector
100 - 240 V AC: 10A
• Power supply for lamp
200 - 240 V AC: 40A