4-2. Manual Rebuild
Described below are procedures based on assumption:
One of the HDDs failed in a RAID5 virtual disk configured with three HDDs.
Replace the failed HDD with new one after turning off the power of the server. Auto Rebuild
feature is disabled for non-hot-swap replacement. Use Manual Rebuild feature to recover
the virtual disk as described below.
Start WebBIOS.
Make sure that the status for the replaced HDD is indicated as "UNCONF GOOD"
in the right frame of the top menu.
47.
Select "PD2" (newly connected HDD) in [Physical Drives].
Содержание N8103-91