5. Troubleshooting
If the server equipped with the disk array controller does not operate normally or some
utilities are disabled, check the following. Follow the action described in the relevant item if
found.
(1) OS cannot be installed.
8
Have virtual disks been created?
Create virtual disks using WebBIOS.
(2) OS cannot be booted.
8
Is the disk array controller inserted into the mating PCI slot to the end
straight?
If not, install the disk array controller correctly.
8
Is the disk array controller inserted into a PCI slot to which some installation
limitation is imposed?
Check the limitation imposed to the installation of the disk array controller
and insert the controller into a correct slot.
If OS is not recognized despite the above actions, the disk array controller may be
defected. Contact your service representative.
8
Are HDDs inserted to the end of the slot?
Install the HDDs in the slot correctly.
8
Are SAS cables connected to the disk array controller, HDDs and/or additional
HDD cage correctly?
Connect the cables correctly.
If OS is not recognized despite the above actions, one or more HDDs may be
defected. Contact your service representative.