1. System BIOS
Express5800/E120d-M Maintenance Guide
70
Chapter 2 Convenient Features
(2) Power Control Configuration submenu
From the
Server
menu, move the cursor to
Power Control Configuration
and then press the <Enter> key to
show its submenus.
For details about the options, see the table below.
Option
Parameter
Descriptions
AC-LINK
Stay Off
[Last State]
Power On
Specify AC link feature. Specify how the DC power state
should be when the AC power is supplied again after loss
of power. (See the table below)
Power On Delay Time Mode
[Manually Setting]
Random
Select a method to specify the delay time before
powering on DC power. Available options are:
"User-specified value" or "random value".
This option is selectable when
Power On
or
Last State
is specified in
AC-LINK
.
Delay Time
[45]-600
Specify the delay time within the range between
"xx"
and 600 seconds. The minimum configurable time is
displayed when executing
Load Setup Defaults
. The
minimum configurable time may differ from the factory
default value.
This menu appears when
Manually Setting
is specified
for
Power ON Delay Time Mode
.
Cold Redundant Mode
[Disabled]
Enabled
Enable or disable Cold Redundancy feature.
[ ]: Factory settings