1. POST Error Message
Express5800/E120d-M Maintenance Guide
110
Chapter 3 Appendix
Error Message
Cause
Solution
B272
PCI Slot 2 - PCIe Link Speed
Error
PCIe bus speed error was detected
on PCI slot 2.
Contact your sales representative.
C000
The error occurred during
fan sensor reading.
An error was detected while reading
fan sensor.
C010
The error occurred during
temperature sensor reading
An error was detected while reading
temperature sensor.
C011
System Temperature out of
the range.
A temperature abnormality was
detected.
It is possible that an ambient temperature of
installation site is high, or a fan has failed or
is clogged. Contact your sales
representative.
C020
The error occurred during
voltage sensor reading.
An error was detected while reading
voltage sensor.
Contact your sales representative.
C021
System Voltage out of the
range.
A system voltage abnormality was
detected.
C040
SROM data read error
An error was detected while reading
FRU data.
C041
SROM data checksum bad
A checksum error was detected
while reading FRU data.
C061
1st SMBus device Error
detected.
An error was detected on 1st SM
Bus.
C062
2nd SMBus device Error
detected.
An error was detected on 2nd SM
Bus.
C063
3rd SMBus device Error
detected.
An error was detected on 3rd SM
Bus.
C064
4th SMBus device Error
detected.
An error was detected on 4th SM
Bus.
C065
5th SMBus device Error
detected.
An error was detected on 5th SM
Bus.
C066
6th SMBus device Error
detected.
An error was detected on 6th SM
Bus.
C067
7th SMBus device Error
detected.
An error was detected on 7th SM
Bus.
C068
8th SMBus device Error
detected.
An error was detected on 8th SM
Bus.
C101
BMC Memory Test
Failed..
An error was detected on BMC.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
C102
BMC Firmware Code
Area CRC check
Failed.
C103
BMC core hardware failure.
C104
BMC IBF or OBF check failed.
An error was detected while
accessing BMC.
C105
BMC SEL area full.
There is not enough space to store
the system event log.
Start up Offline Tools (
Chapter 1, 7. Offline
Tools
) and delete the event logs.