2. List of Windows Event Logs
Express5800/E120d-M Maintenance Guide
120
Chapter 3 Appendix
11
Disk
Error
The driver detected a controller error on Device\Harddisk
X
\DR
X
.
Note
: A different number replaces
X
depending on the connection
status of the disk.
Upon connecting with a USB device,
remote media, and/or Virtual Flash USB
Device
When the below values are 00 in
Details in the event logs
→
Display
,
this event does not affect system operation.
<Word style>
0000: 0068030E 00000001 00000000 C004000B
0008: 00000103 00000000 00000000 002D0800
0010: 00000000 00000000 000427B7 00000000
0018: FFFFFFFF 00000006 00000040 00000000
0020: 12060000 10000008 00000000 0000003C
0028: 00000000 86BAA280 00000000 86BDB008
0030: 00000000 00000000 00000000 00000000
0038: 00000000 00000000 00000000 00000000
0040: 00000000 00000000 00000000 00000000
0048: 00000000 00000000 00000000 00000000
0050: 00000000 00000000
<Byte style>
0000: 0E 03 68 00 01 00 00 00 ..h.....
0008: 00 00 00 00 0B 00 04 C0 .......A
0010: 03 01 00 00 00 00 00 00 ........
0018: 00 00 00 00 00 08 2D 00 ......-.
0020: 00 00 00 00 00 00 00 00 ........
0028: B7 27 04 00 00 00 00 00
・
'......
0030: FF FF FF FF 06 00 00 00 yyyy....
0038: 40 00 00 00 00 00 00 00 @.......
0040: 00 00 06 12 08 00 00 10 ........
0048: 00 00 00 00 3C 00 00 00 ....<...
0050: 00 00 00 00 80 A2 BA 86 ....?
¢
o?
0058: 00 00 00 00 08 B0 BD 86 .....°??
0060: 00 00 00 00 00 00 00 00 ........
0068: 00 00 00 00 00 00 00 00 ........
0070: 00 00 00 00 00 00 00 00 ........
0078: 00 00 00 00 00 00 00 00 ........
0080: 00 00 00 00 00 00 00 00 ........
0088: 00 00 00 00 00 00 00 00
15
ebdrv
Error
lm_sp.c 2450 (ECORE_SUCCESS != ecore_status): An assertion
happened.
Please note provider of this module.
Upon delete a team in BACS
This event does not affect system operation.
134
Microsoft-Windows-
Time-Service
Warning
NtpClient was unable to set a manual peer to use as a time source
because of DNS resolution error on''.
NtpClient will try again in 3473457 minutes and double the reattempt
interval thereafter.
Upon OS Installation
This event does not affect system operation.
1004
IPMIDRV
Warning
The IPMI device driver attempted to communicate with the IPMI BMC
device during normal operation.
However the communication failed due to a timeout.
You can increase the timeouts associated with the IPMI device driver.
When you operate
Windows Server 2008 R2
The above event log may be recorded. Usually, however, IPMI
command retry processing is performed, so there is no operation
problem.