![NEC N8100-1078F Скачать руководство пользователя страница 190](http://html1.mh-extra.com/html/nec/n8100-1078f/n8100-1078f_user-manual_4225291190.webp)
8-8 Troubleshooting
POST Error Messages
When POST detects an error, it displays an error message on the display unit screen. The
following table lists error codes, error messages, and actions to take.
IMPORTANT:
Take a note on the messages displayed before
consulting with your sales agent. Alarm messages are useful
information for maintenance.
The response section in the following table is divided into three types:
Warning:
The message is displayed on screen and the error is logged to the SEL. The system will
continue booting with a degraded state.
Pause:
The message is displayed on the screen and the boot process is paused until the appropriate
input is given to either continue the boot process or take corrective action.
Halt:
The system cannot boot unless the error is corrected.
Error
Code
Error Message
Response
0000
Timer Error
Pause
0003
CMOS Battery Low
Pause
0004
CMOS Settings Wrong
Pause
0005
CMOS Checksum Bad
Pause
0008
Unlock Keyboard
Halt
0009
PS2 Keyboard not found
Not an error
000A
KBC BAT Test failed
Halt
000B
CMOS memory size different
Pause
000C
RAM R/W test failed
Pause
000E
A: Drive Error
Pause
000F
B: Drive Error
Pause
0010
Floppy Controller Failure
Pause
0012
CMOS time not set
Pause
0014
PS2 Mouse not found
Not an error
0040
Refresh timer test failed
Halt
0041
Display memory test failed
Pause
0042
CMOS Display Type Wrong
Pause
0043
~<INS> Pressed
Pause
0044
DMA Controller Error
Halt
0045
DMA-1 Error
Halt
0046
DMA-2 Error
Halt
0047
Unknown BIOS error. Error code = 147 (this is really a
PMM_MEM_ALLOC_ERR)
Halt
0048
Password check failed
Halt
0049
Unknown BIOS error. Error code = 149 (this is really
SEGMENT_REG_ERR)
Halt
004A
Unknown BIOS error. Error code = 14A (this is really ADM_MODULE_ERR)
Pause
Содержание N8100-1078F
Страница 16: ...x This page is intentionally left blank...
Страница 34: ...2 6 General Description Rear View 1 2 3 13 12 11 10 9 8 7 6 5 4...
Страница 36: ...2 8 General Description Internal View 1 2 4 4 4 3 4 2 4 1 5 6 7 8 3...
Страница 38: ...2 10 General Description MOTHER BOARD 1 3 4 5 2 19 2 1 2 6 7 2 8 2 9 2 10 2 11 2 12 13 14 15 2 16 17 18...
Страница 100: ...4 32 Configuring Your Server This page is intentionally left blank...
Страница 150: ...5 50 Installing the Operating System with Express Setup This page is intentionally left blank...
Страница 170: ...6 20 Installing and Using Utilities This page is intentionally left blank...
Страница 182: ...7 12 Maintenance This page is intentionally left blank...
Страница 257: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below...
Страница 266: ...10 10 Internal Cabling Diagrams This page is intentionally left blank...
Страница 268: ...A 2 Specifications This page is intentionally left blank...
Страница 278: ...C 4 IRQ and I O Port Address This page is intentionally left blank...
Страница 328: ...F 18 Installing Windows 2000 This page is intentionally left blank...