![NEC N8100-1078F Скачать руководство пользователя страница 121](http://html1.mh-extra.com/html/nec/n8100-1078f/n8100-1078f_user-manual_4225291121.webp)
Installing the Operating System with Express Setup 5-21
4.
Specify "Complete memory dump" and modify [Dump file:] in the [Write debugging
information] group box.
e.g. Write the debug information in D drive write the file name "MEMORY.DMP".
D:\MEMORY.DMP
5.
Click [Settings] on the [Performance] group box.
The [Performance Options] window appears.
6.
Click [Advanced] tab on the [Performance Options] window.
7.
Click [Change] on the [Virtual memory] group box.
8.
Modify [Initial Size] in the [Paging file size for selected drive] box to the value larger than
[Recommended], and click [Set].
IMPORTANT:
The above-mentioned paging file size is recommended for
collecting debug information (memory dump). The paging file
with initial size large enough to store the dump file in the boot
drive is required.
Correct debug information might not be able to be collected due to
virtual memory shortage when the paging file is insufficient, so set
an enough size of the paging file with the entire system.
For more information on "Recommended" value, see "Partition
Size to be Created" described earlier.
In case the memory is expanded, re-specify the paging file to suit
the new memory size.
To prepare for the situation when any trouble occurred, we
recommend you to press dump switch to confirm that the dump
will be collected normally in advance.
9.
Click [OK].
The message to restart the system may appear according to the modified specification.
In such case, follow the message to restart the system.
Содержание N8100-1078F
Страница 16: ...x This page is intentionally left blank...
Страница 34: ...2 6 General Description Rear View 1 2 3 13 12 11 10 9 8 7 6 5 4...
Страница 36: ...2 8 General Description Internal View 1 2 4 4 4 3 4 2 4 1 5 6 7 8 3...
Страница 38: ...2 10 General Description MOTHER BOARD 1 3 4 5 2 19 2 1 2 6 7 2 8 2 9 2 10 2 11 2 12 13 14 15 2 16 17 18...
Страница 100: ...4 32 Configuring Your Server This page is intentionally left blank...
Страница 150: ...5 50 Installing the Operating System with Express Setup This page is intentionally left blank...
Страница 170: ...6 20 Installing and Using Utilities This page is intentionally left blank...
Страница 182: ...7 12 Maintenance This page is intentionally left blank...
Страница 257: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below...
Страница 266: ...10 10 Internal Cabling Diagrams This page is intentionally left blank...
Страница 268: ...A 2 Specifications This page is intentionally left blank...
Страница 278: ...C 4 IRQ and I O Port Address This page is intentionally left blank...
Страница 328: ...F 18 Installing Windows 2000 This page is intentionally left blank...