5-26
CORRECTIVE MAINTENANCE
GGS-000548-01E
iPASOLINK EX Advanced: O
PERATION
& M
AINTENANCE
4.
Retrieve the
Current Status
, and check if the
ETH LF
alarm is cleared.
YES:
This step ends the procedure.
NO:
Check the associated port of the opposing site as well, then proceed to
the next step.
5.
Retrieve the
Current Status
, and check if the
ETH LF
alarm is cleared. If the
alarm is not cleared, contact NEC for the further maintenance support.
This step ends the procedure.
ETH
This condition indicates that the LOS (Loss of Signal) is detected from the incoming
signal on the indicated Ethernet facility. The problem of this condition pertains to the
optical fiber or to the far-end NE.
Procedure 5-7
1.
Verify that the cable connections are all appropriate.
2.
Check if any alarm(s) is/are issued to the far-end NE. If any exist(s), clear it/
them.
3.
Retrieve the
Current Status
, and check if the
ETH LOS
alarm is cleared. If the
alarm is not cleared, contact NEC for the further maintenance support.
This step ends the procedure.
ETH
This condition indicates that the 10G Ethernet Port on the remote NE fails.
Procedure 5-8
1.
Check that the Ethernet Cables connected to the target port and its associated port
of both local NE and its opposing NE are appropriately connected.
2.
Retrieve the
Current Status
, and check if the
ETH RF
alarm is cleared.
3.
Is
ETH LF
alarm cleared?
YES:
This step ends the procedure.
NO:
Replace the cables, then proceed to the next step.
ETH LOS
ETH RF
Содержание iPASOLINK EX Advanced
Страница 19: ... iv END CONTENTS GGS 000546 01E iPASOLINK EX Advanced INSTALLATION This page is intentionally left blank ...
Страница 21: ...1 2 END OVERVIEW GGS 000546 01E iPASOLINK EX Advanced INSTALLATION This page is intentionally left blank ...
Страница 29: ...2 8 END COMPOSITIONS GGS 000546 01E iPASOLINK EX Advanced INSTALLATION ...
Страница 77: ...GGS 000547 01E GGS 000547 01E Printed in Japan 2016 by NEC Corporation ...
Страница 87: ... x END CONTENTS GGS 000547 01E This page is intentionally left blank ...
Страница 581: ...GGS 000548 01E GGS 000548 01E Printed in Japan 2016 by NEC Corporation ...
Страница 589: ...1 2 END GENERAL GGS 000548 01E iPASOLINK EX Advanced OPERATION MAINTENANCE This page is intentionally left blank ...
Страница 591: ...2 2 END PRECAUTION GGS 000548 01E iPASOLINK EX Advanced OPERATION MAINTENANCE This page is intentionally left blank ...
Страница 775: ...GGS 000549 01E GGS 000549 01E Printed in Japan 2016 by NEC Corporation ...
Страница 777: ... ii END CONTENTS GGS 000549 01E iPASOLINK EX Advanced SPECIFICATION This page is intentionally left blank ...
Страница 779: ...1 2 END INTERFACES GGS 000549 01E iPASOLINK EX Advanced SPECIFICATION This page is intentionally left blank ...
Страница 789: ...3 4 END SYSTEM PERFORMANCES GGS 000549 01E iPASOLINK EX Advanced SPECIFICATION This page is intentionally left blank ...
Страница 791: ...GGS 000552 01E GGS 000552 01E Printed in Japan 2016 by NEC Corporation ...
Страница 793: ... ii END GGS 000552 01E iPASOLINK EX Advaced OPEN SOURCE SOFTWARE SUMMARY This page is intentionally left blank ...