background image

i-Series Gateway

                                                Page 1 

G-6000G-SKE, Rev AA 

 

i-Series Gateway

  

Quick Installation Guide                                

G-6000G-SKE

 

Rev AA/July 2001

 

 
 

Purpose of this Document 

 
This document provides the step-by-step process 
for the complete installation, basic configuration, 
and troubleshooting of the i-Series Gateway. 
 

Related Documentation

  

 
Use this document in conjunction with the 
i-Series Gateway System Administrator’s Guide, 
provided with the unit.  

 
Safety Considerations

 

 

 

 

 

IMPORTANT SAFETY INSTRUCTIONS 

‰

Do not install this product near water. 

Example: In a wet basement location. 

‰

Do not overload wall outlets, as this can 
result in the risk of fire or electrical shock. 

‰

Do not attach the power supply cord to 
building surfaces. Do not allow anything to 
rest on the power cord. Do not locate this 
product where persons walking on it will 
abuse the cord. 

‰

Do not operate the system if chemical gas 
leakage is suspected in the area. Use 
telephones located in some other safe area to 
report the trouble. 

 
 
Product specifications subject to change 
without notice.  
 

Copyright  

” 2001, NEC America, Inc.

Table of Contents 
 

SUPPORT TELEPHONE NUMBER ............ 2 

PREREQUISITES FOR INSTALLATION .. 2 

N

ETWORK 

R

EQUIREMENTS

............................. 2 

ISDN R

EQUIREMENTS 

(

FOR 

A

SYNCHRONOUS 

CONNECTIONS

) ............................................... 3 

I

NFORMATION FOR THE 

S

YSTEM 

A

DMINISTRATOR

............................................ 4 

INSTALLATION COMPONENTS ............... 4 

PARTS NOT PROVIDED WITH THE 
I-SERIES GATEWAY .................................... 4
 

TYPICAL INSTALLATION.......................... 5 

M

OUNTING

..................................................... 5 

C

ONNECTIONS

................................................ 6 

T

ELEPHONY 

W

IRING

....................................... 7 

VT-100 SETUP................................................. 7 

POWER-UP ..................................................... 8 

BASIC CONFIGURATION ........................... 9 

INSTALLATION ENVIRONMENTS......... 10 

S

YNCHRONOUS

-S

ERIAL 

D

EVICE  

(RVP_D

IRECT

)............................................. 11 

A

SYNCHRONOUS

-S

ERIAL 

(RVP_D

IRECT

) .... 12 

IP D

EVICE  

(RVP_IP) ................................... 13 

I

NTRODUCTION

............................................. 13 

DIAL-UP MANAGEMENT CONSOLE ..... 14 

SETUP WIZARD........................................... 15 

TELNET CONNECTION............................. 16 

I

NTRODUCTION

............................................. 16 

P

ROCEDURE

.................................................. 16 

HTML INTERFACE..................................... 16 

OPTIONAL CONFIGURATION ................ 19 

APPENDIX A................................................. 20 

 

Содержание i-Series

Страница 1: ...duct where persons walking on it will abuse the cord Do not operate the system if chemical gas leakage is suspected in the area Use telephones located in some other safe area to report the trouble Product specifications subject to change without notice Copyright 2001 NEC America Inc Table of Contents SUPPORT TELEPHONE NUMBER 2 PREREQUISITES FOR INSTALLATION 2 NETWORK REQUIREMENTS 2 ISDN REQUIREMEN...

Страница 2: ... high power high RF noise devices such as computers fans fluorescent ballast power supplies etc Use good wiring practices Do not run wires over fluorescent lights computers air conditioners etc as this can introduce noise to the modems The distance from the PBX to the i Series Gateway should not exceed 500 feet Obtain the following information from your customer MODE V 35 RS 232 RS 530 ___________...

Страница 3: ...232 Dial feature to work properly for these devices you need to setup each device to accept incoming AT Commands Consult the documentation provided with each device for proper instructions Proper wiring with adequate punch down blocks to connect the Gateway to the PBX Must be wired according to Table 3 page 7 and provide RJ 21 female connector ISDN Requirements for Asynchronous connections Before ...

Страница 4: ...ackets 2 For rack mounting 9 RS 530 type cable for high speed links to CSU DSU or TA For connecting WAN ports on i Series Gateway to CSU DSU or TA 9 System Administrator s Guide The complete guide for the i Series Gateway 9 Quick Installation Guide The condensed installation guide 9 RS 232 DB 25 to DB 9 modem cable male male Note This is a custom made cable For connecting the i Series Gateway to a...

Страница 5: ...allation 0RXQWLQJ You can mount the i Series Gateway in a standard 19 inch communication rack using the brackets provided Figure 2 or you can simply place it on a shelf within the rack Figure 2 Securing the unit to a rack PBX Punch Bl ocks RJ 21 up t o 12 Por t s RJ 21 up t o 12 Por t s peruni t i Ser i es G at ew ay Cr oss Connect W i r es ...

Страница 6: ...VAC outlet Connect as the last step See page 8 C Telephony Interface RJ 21 Wire to a punchdown block and then to the PBX See Table 3 page 7 D WAN1 DB 25 serial straight through Used for a synchronous or asynchronous serial connection Connect to a TA CSU DSU or other network device Note An RS 530 type cable or DB 25 to M34 cable should be used for high speed links to V 35 equipment E LAN RJ 45 Ethe...

Страница 7: ...the i Series Gateway is connected as shown on page 6 2 You must use a communications package for example HyperTerminal to configure and test the i Series Gateway Attach one end of the RS 232 cable to your PC COM1 port and the other end to the Console port connector on the front of the i Series Gateway 3 Set up HyperTerminal as follows a Access Start button Programs Accessories HyperTerminal folder...

Страница 8: ... connected to WAN 1 Solid Orange Ready if an asynchronous ISDN TA is connected and accepting commands but there is no link up in Call Suspend mode or have not dialed it yet Port LEDs Solid Green if connected properly to PBX IMPORTANT If any of the LEDs DO NOT power as explained refer to the System Administrator s Guide for troubleshooting information Front of Unit On initial power up or before the...

Страница 9: ...with a symbol as shown in Figure 3 To enlarge the screen within the VT 100 application Click any corner of the screen Drag the screen to enlarge Check that the screen is bordered by symbols 2 Press any key to continue The Main Menu will appear 3 If you already familiar with using the MI proceed to the next page for information on setting the parameters for different Installation Environments or 4 ...

Страница 10: ... configuration checklist Table 4 Network devices To configure the i Series Gateway with See page A Synchronous Serial device V 35 RS 232 RS 530 via WAN Port RVP_Direct 11 An Asynchronous serial device via WAN Port s 1 or 2 RVP_Direct using RS 232 Protocol 12 An IP device via Ethernet port RVP_IP IP based products from NEC America Inc utilize Voice over IP VoIP technology to deliver remote voice so...

Страница 11: ...pression algorithm for all active telephone ports Provide adequate bandwidth for all users ADPCM 32 on all telephone ports Chapter 4 Port set up Setting Voice Parameters page 61 Enable Disable WAN ports Enable WAN ports to connect to network device WAN 1 Enabled Chapter 4 WAN set up page 72 Set the Sync Rate of the WAN port Match the data rate sync rate of the network device 512 000 kbps Chapter 4...

Страница 12: ...r must assign an IP address for both units in order to configure and test them over a LAN or WAN Basic Configuration Table 6 Configuration Steps You must to Default settings Refer to System Administrator s Guide Enable the WAN port Enable WAN functions WAN 1 Chapter 4 Enabling WAN Port page 73 Set the mode interface type of the WAN port Match the interface type of the network device V 35 Chapter 4...

Страница 13: ...eway and Remote units The network administrator must provide the remote users with User ID s and Connect Passwords if assigned Basic Configuration Table 7 Basic Configuration Steps You must to Default settings Refer to System Admin Guide Set the Telephone Port compression method for all active telephone ports Provide adequate bandwidth for all users ADPCM 32 on all telephone ports Chapter 4 Port s...

Страница 14: ...sible to Rlogin to other connected units to access the MI of those units when the network connection between units is not functioning This connection allows access to all features and functions of the MI and the ability to configure monitor and troubleshoot the unit from a remote location See the figure on page 6 Required Equipment Modem not included with unit Direct analog telephone line for conn...

Страница 15: ... the DB 9 console port The wizard queries the user on the basics of the particular configuration and uses this information to establish the initial configuration programming Standard Console UI vs the Setup Wizard When a unit is first powered up it checks a Setup Wizard flag If the flag is set the standard console UI is displayed If the flag is not set the system asks you to run the Setup Wizard A...

Страница 16: ...mand along with the IP address assigned to the unit See below Telnet address 3 Click OK The MI Welcome Screen is displayed See page 9 HTML Interface Introduction You can configure the i Series Gateway using a standard Web server over an existing LAN connection This feature provides the system administrator complete management capabilities as well as status information for both WAN and PORT connect...

Страница 17: ...Server 3 Select YES for Enabled Set the Timeout to 30 4 Save the settings and Log out of the MI 5 Open any web browser from your PC Example Windows Internet Explorer version 5 X or higher 6 At the http prompt type in the IP Address of the i Series Gateway as shown below 7 The HTML pop up window will appear IMPORTANT INSTRUCTIONS ...

Страница 18: ...ady if a synchronous device is connected to WAN 1 Solid Orange Ready if an asynchronous ISDN TA is connected and accepting commands but there is no link up in Call Suspend mode or have not dialed it yet Port LEDs Solid Green if connected properly to PBX 10 The MI is now accessible for complete i Series Gateway configuration Menu Selections Power LED WAN LEDs Port LEDs ...

Страница 19: ... Extender MI by requiring a password for entry This Admin Password MUST be entered before any configuration parameters are changed Note Both units have their own separate Admin Passwords 2 Connect Password This option provides a secure WAN link between the units If configured a Connect Password is required to connect to the alternate module Note Refer to the System Administrator s Guide Issue AC f...

Страница 20: ...ion Setting Description DTR Normal mode ON Computer must provide DTR signal for modem to accept commands dropping DTR terminates a call Verbal result codes ON Display result codes OFF No echo on offline commands OFF Suppress echo Auto answer ON ON Modem answers on first ring or higher Carrier Detect CD normal ON Modem sends CD signal when it connects with another modem drops CD on disconnect The f...

Страница 21: ... back of the modem 3 Power up the modem The modem runs a series of self diagnostic tests 4 Plug the other end of the modem cable into the port labeled Console port on the front of the i Series Gateway 5 Power up the i Series Gateway unit The modem status LED for Data Terminal Ready should be RED indicating the modem is ready to receive data Note Refer to the Modem User s Guide for specific LED inf...

Страница 22: ...8 Fax 203 926 5458 cng nec com Other Important Telephone Numbers Sales 203 926 5450 Customer Service 203 926 5444 Customer Service FAX 203 926 5454 Technical Service 203 925 8801 Discontinued Product Service 900 990 2541 Technical Training 203 926 5430 Emergency Technical Service After Hours 203 929 7920 Excludes discontinued products ...

Отзывы: