3. Setting Up Windows Server 2012
Express5800/R320c-E4, R320c-M4, R320d-E4, R320d-M4 Installation Guide (Windows)
77
Chapter 1 Installing Operating System
4. Enter the team name and click
Next
.
5. Select the adapters to include in the team and click
Next
.
Note
Check "PCI bus" and "Function (*)" of adapters to be included in the team.
Use adapters of the same functionality. Create a team with an adapter having smaller PCI
bus number and an adapter having larger PCI bus number.
(*) "Function" can be verified in
General
tab of
Properties
window.
PCI bus:
Smaller value (PCI module #0 side)
Larger value (PCI module #1 side)
Function:
0 (Port #0 side)
1 (Port #1 side)
Example:
Team 0
PCI bus (smaller value), Function 0 (Port #0 side)
PCI bus (larger value), Function 0 (Port #0 side)
Team 1
PCI bus (smaller value), Function 1 (Port #1 side)
PCI bus (larger value), Function 1 (Port #1 side)
6. Select
Adapter Fault Tolerance
,
Adaptive Load Balancing
, or
Switch Fault Tolerance
as a team
mode. Click
Next
.
Note
Virtual Machine Load Balancing
is displayed when Hyper-V feature is enabled.