Updating the System BIOS
Updating ftServer System Firmware
3-3
4. Use the
ftsmaint
command to verify that you are starting from a known, good
state. At this point, both CPU-I/O enclosures should be operating duplexed.
#
/opt/ft/bin/ftsmaint ls 0
H/W Path : 0
Description : Combined CPU/IO
State : ONLINE
Op State : DUPLEX
Reason : SECONDARY
LED (Green) : ON
LED (Yellow) : OFF
LED (White) : ON
Modelx : AA-G94340
Firmware Rev : 1.3:90
ECO Level : 37
Min Partner ECO Level : 0
Serial # : 401318
MTBF Fault Count : 0
MTBF Last Timestamp : None
MTBF Threshold : 1200
MTBF Value : 0
MTBF Type : useThreshold
Logic Revision : 18023
Then run the following command:
#
/opt/ft/bin/ftsmaint ls 1
N O T E
To determine what model your system is, type the
ftsmaint lsSystem
command. The model is identified
in the
Description
field.
5. Obtain the latest BIOS image for the Express5800/ftServer and copy it to the
ftServer tmp folder.