Troubleshooting
7-11
The system does not operate according to the configured settings of "Automatic
Restart" at the occurrence of error.
→
The system may or may not restart automatically even if the "Automatic Restart"
settings are made at occurrence of an error is set. If the system does not restart
automatically, restart it in manual mode.
The power cannot be turned off while the blue screen of Windows Server 2003,
Enterprise Edition is displayed.
→
The forced power-off (forced shutdown) procedure is necessary to turn off the power
with the blue screen displayed. Keep pressing the POWER switch for 4 seconds.
Pressing the POWER switch only once does not turn off the power in this case.
The server is not found on the network:
Is the LAN cable connected?
→
Make sure to connect the LAN cable to the network port on the rear of the server.
Also make sure to use the LAN cable that conforms to the network interface
standard.
Have the protocol and service already configured?
→
Install the distinctive network driver for the server. Make sure that the protocol,
such as TCP/IP, and services are properly specified.
Is the transfer speed correct?
→
Open the [Network Property] dialog box in Control Panel to specify the "Link
Speed & Duplex" value the same as the value specified for HUB.
Transfer speed can be fixed by PROSet II.
Select an adapter to modify the setting from the tree on the left, for 100Base
adapter, click the [Advanced] tab and make settings at "Link Speed & Duplex".
For 1000Base-T adapter click the [Link Config] tab.
Select [Enabled] "Auto Negotiation" and specify the transfer speed at
"Negotiable Speed and Duplexes".
(Only check the transfer speed to use.)
Icon of drive A is changed to that of removal disk:
→
Does not cause any problem.
Содержание Express5800/340Hb-R N8800-047F
Страница 1: ...N8800 047F 073F NEC Express5800 340Hb R User s Guide 1st Edition 3 2005 856 125126 901 A ...
Страница 14: ...viii This page is intentionally left blank ...
Страница 17: ...Precautions for Use 1 3 Label A Label B Label C Label D ...
Страница 20: ...1 6 Precautions for Use Label A Label B Label C ...
Страница 22: ...1 8 Precautions for Use Label A Label B Label C ...
Страница 51: ...General Description 2 15 Chassis Board Layout Clock board Interface board Back panel ...
Страница 76: ...2 40 General Description This page is intentionally left blank ...
Страница 90: ...3 14 Windows Setup and Operation 7 Configure the mirror of the extended volume ...
Страница 124: ...3 48 Windows Setup and Operation This page is intentionally left blank ...
Страница 158: ...4 34 System Configuration This page is intentionally left blank ...
Страница 171: ...Installing and Using Utilities 5 13 ...
Страница 186: ...5 28 Installing and Using Utilities DIMM Allows the information of DIMM on the CPU modules to be viewed ...
Страница 244: ...6 12 Maintenance This page is intentionally left blank ...
Страница 245: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown ...
Страница 278: ...7 34 Troubleshooting This page is intentionally left blank ...
Страница 306: ...8 28 Option This page is intentionally left blank ...
Страница 312: ...B 4 IRQ and I O Port Address This page is intentionally left blank ...