ftSMC Component Properties
3-10
Express5800/320Ma: Technical Reference Guide
Limit of Event Log Entries
The maximum number of event log entries to include in any
message. By default, if the specified interval has more than 256
entries in either the system or the application log, the last 256
entries are sent as part of the message.
Line1
Contains the text on the top line of the front panel LCD.
Line2
Contains the text on the bottom line of the front panel LCD.
LinkDataRate
The current signalling rate of the link.
LinkProtocol
The storage command protocol running on the link.
Long Idle Re-send Count
The number of re-send attempts, separated by
Long Idle Time
Between Re-sends
, that ftServer Manager will make before
dropping the current alarm message.
Long Idle Time Between
Re-sends
The long idle time, in seconds, between attempts to re-send an
alarm. After a number, defined by
Medium Idle Time Between
Re-sends
, of unsuccessful attempts to send an alarm message,
ftServer Manager waits this long before it attempts to re-send the
alarm. After a number of unsuccessful attempts, defined by
Long
Idle Re-send Count
, ftServer Manager will quit attempting to send
the oldest alarm message and move to the next one in the alarm
queue.
LowerThresholdCritical
Threshold values specify the ranges for determining whether the
monitored component is operating under normal, noncritical, critical,
or fatal conditions. Depending on the sensor, values are in degrees
Celsius (
o
C), millivolts (mV), revolutions per minute (rpm), or
milliamperes (mA).
LowerThresholdFatal
Threshold values specify the ranges for determining whether the
monitored component is operating under normal, noncritical, critical,
or fatal conditions. Depending on the sensor, values are in degrees
Celsius (
o
C), millivolts (mV), revolutions per minute (rpm), or
milliamperes (mA). This property is not configurable and attempting
to change it will display the value of Not Set.
LowerThresholdNonCritical
Threshold values specify the ranges for determining whether the
monitored component is operating under normal, noncritical, critical,
or fatal conditions. Depending on the sensor, values are in degrees
Celsius (
o
C), millivolts (mV), revolutions per minute (rpm), or
milliamperes (mA).
LowResynchPriorityMbs
The low value for I/O bandwidth to disk, a portion of which will be
used for RDR disk resynchronization operation. The default value of
this property is 5Mbps.
Table 3-1. ftSMC System Inventory Component Properties (Continued)
Property
Description
Содержание Express5800/320Ma
Страница 1: ...NEC Solutions America Inc NR550 Express5800 320Ma Technical Reference Guide...
Страница 10: ...Preface x Express5800 320Ma Technical Reference Guide...
Страница 24: ...ASN Connection Retry Cycle 2 10 Express5800 320Ma Technical Reference Guide...
Страница 52: ...ftSMC Component Actions 3 28 Express5800 320Ma Technical Reference Guide...