4-16 Configuring Your Server
Option
Parameter
Description
Your Setting
Post Error Pause
Disabled
[Enabled]
Specify whether to stop the POST once
at the end of POST if an error occurs
during the POST.
AC-LINK
Stay Off
[Last State]
Power On
Specify the state of power when the AC
power to the server is turn off once and
then on.
Power ON Delay
Time (Sec)
[20] - 255
Specify the power on delay time within
the range between 0 and 255 seconds.
The time specified is valid when "Power
On" or "Last State" is specified for AC
LINK.
Platform Event
Filtering
Disabled
[Enabled]
Specify whether to enable or disable the
platform event filtering (PEF) feature.
[ ]: Factory-set
IMPORTANT:
To power on the server from the UPS (Uninterruptible
Power Supply), select [Server] - [AC LINK] - [Power On].
The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC LINK."
Setting of AC LINK
System status before AC power off
Stay Off
Last State
Power On
Operating
Off
On
On
Aborting (DC power being off also)
Off
Off
On
Forced shutdown
Off
Off
On
* Press the power switch continuously for four seconds or longer. This forcibly turns off the power.
Содержание Express5800/120Rh-1
Страница 16: ...x This page is intentionally left blank ...
Страница 148: ...4 58 Configuring Your Server The detailed settings is continued to the next page Click Next to view more information ...
Страница 159: ...Configuring Your Server 4 69 Use this menu to define several physical drives PD as a disk group DG ...
Страница 183: ...Configuring Your Server 4 93 3 Setting menu for VD 0 is displayed ...