1. POST Error Message
Express5800/T110f-S, R110f-1E, T110f-E Maintenance Guide
140
Chapter 3 Appendix
(2/2)
BIOS Message on
Upper LCD Line
Description Action
System
Configuration
change is detected
The CPU or memory configuration
has changed since the previous
startup.
If this message appears even when no configuration
change has been made, contact your sales
representative
PCI Slot #x
Uncorrectable
Error (x: 1-2)
(Express5800/T110
f-S, T110f-E)
An uncorrectable error occurred in
PCI slot #x.
PCIxx Slot
UnCorrectable
Error (xx: 1A, 1B)
(Express5800/R110
f-1E)
An uncorrectable error occurred in
PCI slot #xx.
Install the PCI boards correctly. If the error is detected
again, contact your sales representative.
PCI-Express
Uncorrectable
Error 1
An uncorrectable device error
occurred in PCI Express.
Contact your sales representative.
DIMM #x
Correctable Error
(x: 1-4)
A correctable memory error occurred
in DIMM #x.
The error was corrected. If the same error occurs after
restarting, install the DIMM correctly. If the error is
detected again, contact your sales representative.
DIMM #x
Uncorrectable
Error (x: 1-4)
An uncorrectable memory error
occurred in DIMM #x.
Contact your sales representative.
Memory
Reconfigured
A failed DIMM was detected and
degraded.
Contact your sales representative.