1. POST Error Message
Express5800/T110f-S, R110f-1E, T110f-E Maintenance Guide
137
Chapter 3 Appendix
(4/4)
Error Message
Description
Action
C10B
BMC operational code
corrupted.
C10C
BMC update firmware
corrupted.
BMC device (chip) error
C10D
Internal Use Area of BMC
FRU corrupted.
Chassis information is incorrect.
C10E
BMC SDR Repository empty.
BMC device (chip) error
C10F
IPMB signal lines do not
respond.
SMC (Satellite Management
Controller) failure
C110
BMC FRU device failure.
Failure of the SROM for storing
chassis information
C111
BMC SDR Repository
failure.
Failure of the SROM for storing
sensor data record information
C112
BMC SEL device failure.
BMC device (chip) failure
C113
BMC RAM test error.
BMC RAM error
C114
BMC Fatal hardware error.
BMC error
C11B
BMC Mezzanine card is not
found.
BMC Mezzanine card is not
mounted.
C11C
BMC Mezzanine partition
is invalid.
BMC Mezzanine partition is
invalid.
Turn off the power, disconnect the
server from the outlet, wait for at least
30 seconds, and restart the server. If
the error occurs again, contact your
sales representative.
C11D
BMC is in Forced Boot
Mode.
The Forced Boot Mode of BMC
was detected.
Check the jumper switch on the
motherboard. Unplug the power
cable, wait for at least 30 seconds,
and then restart the server. If the
error is detected again, contact your
sales representative.
C11E
Communication with BMC
was failed in previous
boot.
Communication with BMC was
failed in previous boot.
Contact your sales representative.
C200
The error occurred during
memory configuration
check.
The memory information could
not be obtained.
Turn off the power and restart the
server. If the error is detected again,
contact your sales representative.
C201
Memory Configuration
change is detected.
The memory configuration has
changed since the previous
startup.
When
Check previous system
Config
is enabled in
server
of the
BIOS settings, this message appears
if the configuration was changed
since the previous startup. If this
message appears even when no
configuration change has been made,
contact your sales representative.
C202
The error occurred during
CPU configuration check.
The CPU information could not
be obtained.
Turn off the power and restart the
server. If the error is detected again,
contact your sales representative.
C203
CPU Configuration change
is detected.
The CPU configuration has
changed since the previous
startup.
When
Check previous system
Config
is enabled in
server
of the
BIOS settings, this message appears
if the configuration was changed
since the previous startup. If this
message appears even when no
configuration change has been made,
contact your sales representative
C300
Out-of-band setup
configuration failure
Invalid access to BMC
Mezzanine card
Contact your sales representative.
C301
SDR mismatch error
Inconsistency in the hardware
information of the sensor data
record was detected
C322
No information for system
power consumption check
The information for system
power consumption was not
detected.
Contact your sales representative.
C501
Intel(R) Node Manager is
in Recovery Mode
The Recovery Mode of Intel(R)
Node Manager was detected.
Check the jumper switch on the
motherboard. Unplug the power
cable, wait for at least 30 seconds,
and then restart the server. If the
same error is detected again, contact
your sales representative.