Site Preparation
65
Environmental Requirements
Barometric Pressure
The 7401 is designed to operate within the following barometric
pressure conditions:
•
Maximum operating altitude: 3000 m (9843 ft)
•
Operating range of pressure: 105 kPa to 69 kPa (15.2 lb./in. to
10.0 lb./in.)
Temperature
The 7401 is designed to operate over the temperature ranges shown
below. Continuous operation must be avoided, however, at or near the
temperature extremes, or in locations where temperature changes
exceed the temperature restrictions.
Temperature Parameter Restriction
Operating
5oC to 45oC (41oF to 113oF), dry bulb
Storage
-10oC to 50oC (14oF to 122oF), three months
Shipping
-40oC to 60oC (-40oF to 140oF), one week
Dew Point
26oC (79oF) maximum
Humidity
The 7401 is designed to operate within the humidity ranges shown
below. Continuous operation must be avoided, however, at or near the
humidity limits, or in locations where humidity changes exceed the
humidity restrictions.
Humidity Type
Restriction
Relative
10% to 90%
Maximum change rate
10%/60 minutes
Storage
10% to 90% relative humidity, three months
Shipping
5% to 95% relative humidity, one week
Содержание EasyPoint 7401
Страница 1: ...NCR EasyPoint 7401 Release 2 4 Site Preparation Guide 19797 NCR B005 0000 1255 Issue C...
Страница 8: ...vi Site Preparation...
Страница 20: ...2 Site Preparation 7401 45xx Model 19889d...
Страница 57: ...Site Preparation 39 Terminal with K521 Wall Mount 19291 7 in 8 7 in 4 in 7 8 in K521...
Страница 58: ...40 Site Preparation 17715 Wall Bracket Lag Screws 4 1 2 m 48 in Recommended Height from Floor K521 Wall Mount...
Страница 61: ...Site Preparation 43 17593 Wall Bracket Lag Screws 6 1 2 m 48 in Recommended Height from Floor K525 Wall Mount...
Страница 62: ...44 Site Preparation Mounting Screw on both sides 17735 K525 with K530 Pole Mount Straps...
Страница 84: ......
Страница 89: ......
Страница 90: ...B005 0000 1255 May 2002 Printed on recycled paper...