- Change in the
tmr2
parameter. The maximum range of the parameter is 99 min. 59 s!
The
tmr2
parameter is set in the same way as tmr1.
CAUTION:
This timer is not used for this machine configuration and, therefore, it must
be set to 00 min. 00 s! If it were set in another way than specified, it would
just extend the washing cycle time. However, no function of the machine is
active during this time!
-
SETTING THE TIME OF ACTIVATION AND DEACTIVATION OF THE TIME HEATING
(PREHEATING)
A diagram for switching the heating element on and off according to set time is shown in Fig.
6.3.2-6. The following sections describe the procedure for setting of time heating.
Figure 6.3.2-
6
Diagram of switching the heating element on and off with the activated and
deactivated time heating
dAY oF
– time heating is off
Heating is permanently enabled
and controlled by the
S1oF
and
S1on
parameters.
dAY on
– time heating is on
Heating is enabled according to the
following parameter setting:
ti on = 06 00
ti oF = 18 00
and in this interval it is controlled by the
S1oF
and
S1on
parameters.
Содержание ADS800
Страница 5: ...P a g e 5 61 Fig 1 Front view of the machine 1 102 1 101 1 2 1 71 1 72 1 1...
Страница 6: ...P a g e 6 61 Fig 2 Left view of the machine SQ1 HS1 2 102 2 101 RT1 ST1 T1 See Fig 2a See Fig 2b...
Страница 9: ...P a g e 9 61 Fig 2c detailed view of housing 2c 91 1 2c 3 2c 93 1 2c 2 2c 92 1 2b 4 2c 1...
Страница 10: ...P a g e 10 61 Fig 3 Rear view of the machine 3 1 3 91 1 See Fig 3a Name plate 3 2 3 102 3a 1...
Страница 12: ...P a g e 12 61 Fig 4 Right view of the machine 2 102 4 103 4 102 4 51 4 1 4 61 See Fig 7 4 101 4 91 1 4 91 2...
Страница 18: ...P a g e 18 61 Fig 5 Basic dimensions of 001 ADS SFM800...
Страница 32: ...P a g e 32 61...
Страница 58: ...P a g e 58 61 10 1 Description of electrical functions and a set of wiring diagrams separate annex...
Страница 61: ...P a g e 61 61 Annex 10 4 Machine operation records Date Completed works on the machine Name and signature...