17
4 Installation and Connection
2. Mount at the install location.
Use the spigot to align the unit with the mating device and
secure it using a hex socket head cap screw.
※ Hex socket head cap screws and couplings are not
provided.
<Equipment side mounting part recommended machining dimensions>
3. After tightening the screws, make sure that there is no gap
between the unit and the partner device.
・
Do not hold the cables or output shaft during transportation.
This may result
in a fault.
・
Do not subject the output shaft to strong impacts.
This may result in a fault.
・
When installing the unit vertically, install the unit with the output shaft facing
down, as failing to do so may result in grease flowing into the unit.
This may
result in a fault.
Couplings
Couplings
Equipment side
mounting part
Mounting hole
(M4)
Spigot receiver
Hex socket head cap screw (M4)
Hex socket head cap screw (M3)
Mounting hole (M4)
Spigot receiver
Equipment side
mounting part
Unit
Unit
32H7
48
45°
When fixing from equipment side: 4×Φ4.5
When fixing from the unit side: 4×M3
Caution