21
4 Installation and Connection
4.2 Connection
■Unit Connection
Connect the power supply.
A power supply with an appropriate current capacity should be
prepared by the customer.
Operating current per unit:
Power cable:
Do not connect directly to AC power.
This may result in a fire or a fault.
Power Source Voltage:
24 VDC±10%
Rated Current:
0.65 A
Maximum Current:
1 A
Wire Used:
H-VFF 0.5SQ
Cable Length:
1 m
Wire Color:
Red (+2 4 V)/
Black (0 V)
Cable Termination:
Stranded Wire
Caution