NBE RTB 10 Скачать руководство пользователя страница 23

 

 

Ready To Burn

 

Ready To Burn: Version 1.0 October 2015 

 

Page 

22

 of 

24

 

 

WARRANTY 

All products purchased from 

RTB-UK

 are covered by the standard 1-year parts and labour 

warranty. This includes 12 months warranty on the products valid from the date of receipt. 
A  2-year  parts  only  warranty  is  granted  with  the  completion  of  the 

Warranty 

Registration

.  

 

Boiler vessel warranty. 

A two-year manufacturer’s parts warranty is available on the boiler vessel only if installation 
is  done  to  manufacturer  installation  instructions,  the  appropriate  commissioning 
documentation is completed and the system is registered on the Stokercloud server. 
 

Extended warranty. 

The parts warranty can be extended to 3 years and the boiler vessel to 10 years under the 
conditions out lined below.  

 

Installed by certified RTB installation company 

 

Products registered on Stokercloud 

 

Controller is online 

 

Consecutive annual services by certified RTB service company 

 

Note:  Electrical  Igniters  are  not  covered  under  the  warranty,  as  they  are  a 
wearable part.  

The  warranty  only  covers  manufacturing  and  material  defects.  In  case  of  product  failure  of  the 
system when under warranty, 

RTB-UK

 will replace the spare part at no charge to the buyer within 

the first year. Buyer will be responsible for the installation or replacement of the part thereafter. If 

RTB-UK

 offers replacement of the defective part the purchaser shall send the part to 

RTB-UK

 for 

replacement.  Guarantee  shall  be  invalid  if  product  failure  is  due  to  circumstances  caused  by  the 
buyer;  either  by  accident  and/or  abuse  of  the  product,  poor  installation,  inadequate  cleaning, 
chimney  conditions,  as  well  as  circumstances  where 

RTB-UK

  has  no  influence.  In  addition,  the 

warranty is invalid due to misuse of the burner for example using fuel that is not approved by 

RTB-

UK.

 

The warranty does not cover parts such as the electrical igniter. The buyer is obligated to check 

the  goods  immediately  upon  receipt.  If  the  buyer  declares  that  the  delivery  was  inadequate  or 
defective,  the  customer  must  immediately  and  without  delay  make  a  written  claim  with 

RTB-UK

Returns  are  only  made  by  agreement  with 

RTB-UK

.  To  the  extent  that

  RTB-UK

  is  liable  to  the 

purchaser, 

RTB-UK’s

 liability is limited only to direct loss and not to damages incurred by connected 

equipment and/or indirect damage, loss of earnings, operating losses, connection costs, etc.  

Responsibilities: 

RTB-UK

  assumes  no  responsibility  as  a  result  of  the  purchaser's  legal  relations 

with third parties. All orders are accepted subject to force majeure, including war, civil unrest, natural 
disasters,  strikes  and  lockouts,  failing  supplies  of  raw  materials,  fire,  damage  to

  RTB-UK

  or  its 

supplier  network,  lack  of  transport  opportunities,  import  /  export  prohibitions  or  any  other  event 
which prevents or restricts 

RTB-UK’s

 ability to deliver. 

RTB-UK

 has in cases of force majeure, the 

right to cancel the transaction or any part thereof, or to deliver the agreed product as soon as the 
obstacle  to  normal  delivery  has  lapsed.  In  cases  of  force  majeure, 

RTB-UK

  will  not  be  held 

responsible for any losses incurred by the purchaser due to non-delivery. 

RTB-UK

 will not be held 

responsible  for  any  changes  and/or  faults  related  to  price  changes,  sold  out  items  or  changes  to 
specifications in the product manual. It is the buyer's responsibility to register the equipment to the 
appropriate authorities. If any disputes arise between the authorities and the purchaser, 

RTB-UK

 will 

be held harmless from any claims or disputes.  

 
 
 
 
 
 
 

Содержание RTB 10

Страница 1: ......

Страница 2: ...sion 7 boiler control system and therefore menus are not described in this manual It is recommended to study the menus before initial start up Keep this manual so you always have it available if you e...

Страница 3: ...ion of your system must cease immediately and must remain so until a solution to the draft problem has been resolved Continuing operation may result in death or injury Always read the manual before in...

Страница 4: ...inistrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke...

Страница 5: ...nimum 24W 24W 20W 20W 34W 34W 82W 82W EN303 5 2012 Class 5 5 5 5 5 5 5 5 Controller Version V7 V7 V7 V7 V7 V7 V7 V7 Width mm 506 506 506 506 655 655 723 723 Depth mm 843 843 843 843 843 843 1043 1043...

Страница 6: ...23 mm Height 1300 mm Depth 845 mm Pellet Capacity 320 kg Compatible with RTB sizes 10 16 30 50kW VAC 10 16 Hopper Width 506 mm Width Boiler Hopper 506 mm Height 1827 mm Depth 845 mm Pellet Capacity 50...

Страница 7: ...output 40W Weight 12kg 30kW burner Hourly fuel consumption At 25kW output 5kg Power consumption At nominal output 45W Weight 15kg 40 60kW burner Hourly fuel consumption At 50kW output 10kg Power consu...

Страница 8: ...ler shorten its working life and void any warranty claims The RTB boiler range is not suitable for installation outside The boiler room should be well lit with enough area to refuel the boiler and wor...

Страница 9: ...ved Document J Section 2 and can meet the above requirement The heights and separation distances may have to be increased in particular cases where high wind exposure surrounding tall buildings high t...

Страница 10: ...ing windy conditions Recommended permanent free area vent sizes RTB 10 10kW 85cm RTB 16 17kW 144 5cm RTB 30 25kW 212 5cm RTB 50 46kW 382 5cm HYDRAULIC SYSTEM The RTB range of boiler must be installed...

Страница 11: ...d 2 DHW with 3 port valve Typically used when the DHW cylinder or the coil surface area is large The house is not supplied with heat while producing hot water The house must therefore be able to manag...

Страница 12: ...Ready To Burn Ready To Burn Version 1 0 October 2015 Page 11 of 24 ELECTRICAL SYSTEM Wiring diagram V7 V10...

Страница 13: ...Ready To Burn Ready To Burn Version 1 0 October 2015 Page 12 of 24 Wiring diagram extension module V7 V10...

Страница 14: ...Optional output for equipment EKSTRA 3 PE N L9 Boiler Compressor Valve 1 EKSTRA 3 PE N L10 Boiler Compressor Valve 2 BUS GRD TX RX Expansion module ILT V1 V V2 O2 controller KONTAKT K K1 External ON...

Страница 15: ...t be made to the router these adapters can be used They can establish a connection to your router through your household power cables This solution allows for easy PLUG and PLAY Step 2 You can find yo...

Страница 16: ...ailable for the following devices This will allow you to monitor your boiler from anywhere in the world For Apple devices search StokerApp For Android devices search StokerControl For Windows devices...

Страница 17: ...nal graphs and burner reaction pattern and make adjustments based on the observations Any changes made remotely can be viewed in the event log section of the controller menu After adjusting it should...

Страница 18: ...troller by going to the menu Auger Auger capacity 6 min enter pellet weight Step 2 Adjusting the Fan 1 Turn on the system by pressing the ON OFF button on the controller 2 Go to the Regulation menu se...

Страница 19: ...can be easily performed Boiler All surfaces inside the boiler must be brushed clean of any deposits and the ash can must be emptied Pay special attention to any build up of ash in the rear smoke cham...

Страница 20: ...Mount it correctly Too high chimney draft Install a draft stabilizer in the chimney Set electric ignition power up Reduce the fan speed during ignition Stopped fan Check if the fan can run replace if...

Страница 21: ...d pipes in the installation Insulate with pipe insulation Too many electric ignitions Flow in the system is fluctuating Set the pressure controlled circulation pump to fixed pressure External thermost...

Страница 22: ...ort un insulated smoke pipe 0 3 m Do not cool down the smoke unnecessarily before it reaches the chimney Draft stabilizer Stabilizes the draft and provides the chimney with dry air High boiler tempera...

Страница 23: ...es where RTB UK has no influence In addition the warranty is invalid due to misuse of the burner for example using fuel that is not approved by RTB UK The warranty does not cover parts such as the ele...

Страница 24: ...oduct identification Pellets Systems RTB 10 RTB10 VAC RTB 16 RTB16 VAC RTB 30 RTB 30 VAC RTB 50 RTB 50 VAC is in conformity with the provisions of the following EC directive s including all applicable...

Страница 25: ...esh air intake building regs part J Y N Air intake size cm 11 Has the system been quick calibrated by weighing the pellets Y N Weight of pellets in 6 minutes g 12 Has the client been informed about th...

Отзывы: