46
O
perating the Boiler
Setting the Pump Overrun Time
Display
Description
Pu
m
p overrun ti
m
e (
m
in)
The pu
m
p overrun ti
m
e is the duration the circulation pu
m
p
continues to run between the space heating supply or return
te
m
perature reaching the set point and the burner turning off.
I
f
the space heating supply or return te
m
perature re
m
ains outside
of the boiler operation te
m
perature range for a set period, the
pu
m
p stops for 10
m
ins, runs again for 5
m
ins, and then repeats
the cycle.
Ɣ
Default: 40
m
inutes
Ɣ
Range: 3–40
m
inutes
Setting the DHW Max Heat Capacity
Display
Description
DHW
m
ax heat capacity (%)
This
m
enu is used to configure the desired DHW capacity. When
the boiler operates in the Nor
m
al
m
ode, the
m
ax DHW capacity
is li
m
ited to the set value (%).
DHW Max Heat Capacity Setting Range
Range
Remarks
[DHW
M
in Heat Capacity set
point + 20%] – 100%
Default: 100%
Setting the DHW Min Heat Capacity
Display
Description
DHW
m
in heat capacity (%)
This
m
enu is used to configure the desired DHW capacity. When
the boiler operates in the Nor
m
al
m
ode, the
m
in DHW capacity
is li
m
ited to the set value (%).
DHW Min Heat Capacity Setting Range
Range
Remarks
DHW
M
in Heat Capacity –
[DHW
M
ax Heat Capacity set
point - 20%]
Default: DHW
M
in Heat
Capacity (%)
Setting the Min Heat Capacity for Space Heating
Display
Description
Space heating
m
in heat
capacity (%)
This
m
enu is used to configure the desired space heating
capacity. When the boiler operates in the Nor
m
al
m
ode, the
m
in
space heating capacity is li
m
ited to the set value (%).
Space Heating Min Heat Capacity Setting Range
Range
Remarks
Space Heating
M
in Heat
Capacity – [Space Heating
M
ax
Heat Capacity set point - 20%]
Default: Space heating
m
in
heat capacity (%)
Setting the Pump Freeze Protection Temperature
Display
Description
Pu
m
p freeze protection
te
m
perature (°C)
This
m
enu is used to configure the circulation pu
m
p freeze
protection te
m
perature.
When the space heating supply te
m
perature stays below the set
value for longer than 10 seconds, the boiler runs the circulation
pu
m
p to prevent freeze da
m
age (the pu
m
p runs for 10
m
inutes,
then stops for 1
m
inute).
Ɣ
Default: 10°C
Ɣ
Range: 6–10°C
Setting the Anti-fast Cycling Time
Display
Description
Anti-fast cycling ti
m
e (
m
in)
The anti-fast cycling ti
m
e is the duration that the boiler stops
its space heating operation when the space heating supply or
return te
m
peratures reach the set values for boiler operation
stop te
m
peratures. The boiler will not resu
m
e space heating
until the duration elapses, even when the space heating supply
or return te
m
peratures return to within the set ranges.
Ɣ
Default: 3
m
inutes
Ɣ
Range: 0–20
m
inutes