All of the necessary temperature sensors connect to the controller: three of them measure the 
temperature of the water in the water heater, one in the solar collector and one in the boiler. The 
temperature sensors should be mounted as described in table 1.

Table 1

Temperature 

sensor

Temperature

Mounting 

Sensor 1

t1

In the bottom section of the water heater, beside the electrical heater 

Sensor 2

t2

In the upper section of the water heater, above the boiler's serpentine 

Sensor 3

t3

pt1000 – in the solar collector

Sensor 4

t4

NTC – in the boiler

Sensor 5

t5

In the middle section of the water heater, above the solar collector's 
serpentine

If   you   want   to   remotely   monitor   and   control   your   water   heater's   performance   through   your 
computer, you can connect a radio modem NRM-868 to the controller to build a wireless network.

Information displayed on the main screen

The display has four main screen designs. They show different screen view for the main work 

conditions of NHC-H42: Water Heater Off, Water Heater On, Settings and Graphics

1. Design I – Water Heater Off

When the water heater is off, the screen displays date, time, the current temperature of the water, 
measured on the top section of the water heater, and the condition of the tank's anode protector. If 
there is an error, the anode protector's indicator switches with the error message and there might be 
a sound alarm too. When the water heater is off, the screen is darker.

If the time is not set, the clock blinks. The temperature regulator has a battery that keeps the time  
settings if the mains power supply is off for short time. The battery keeps the time settings for  
maximum 18 hours, after that the clock turns off and needs to be set again.

NHC-H42-2 Reference Manual ver 1.6

стр. 4 / 18

System date

System time

Temperature of the water

in the top section of the

water heater

The anode protector's

condition or an error

message, if any

Содержание NHC-H42-2

Страница 1: ...ller has a contrast LCD display four control buttons and a LED indication for the electrical heater NHC H42 has a built in electronic temperature regulator to control a mono phase or three phase elect...

Страница 2: ...t day Prevents the freezing of the water heater or of the solar collector Information about the condition of the anode protector Information if higher than 30mA leakage from the electrical heater to t...

Страница 3: ...an electrical heater and two differential temperature regulators adapted for a solar collector installation and a heating installation with a boiler or a fireplace The difference in the differential t...

Страница 4: ...on the main screen The display has four main screen designs They show different screen view for the main work conditions of NHC H42 Water Heater Off Water Heater On Settings and Graphics 1 Design I Wa...

Страница 5: ...the temperature measured by the temperature sensor in the bottom section is displayed in this field Since the hot water goes up to the top section of the water heater and then to the pipes it is poss...

Страница 6: ...llation When the pumps are on and the differential temperatures t1 and t2 go below the limits set from the menu Dif Temp 1 2 line Pump Off the relevant circulation pump turns off To help the outer hea...

Страница 7: ...upper one appears on the display For the boiler s installation DHW priority mode boiler s circulation pump turns on if t2 or the temperature of the boiler t4 has to be higher than the temperature in t...

Страница 8: ...electrical heater is activated from the menu System Setting its turning on and off depends on the temperature in the bottom section of the water heater measured by Sensor 1 When changing the differen...

Страница 9: ...eater s control By pressing the View Enter button all the possible data appears successively in the following order Set temperature for heating with the electrical heater Temperature measured in the b...

Страница 10: ...heater It is broken or disconnected S1 E2 A breakdown in the temperature sensor in the bottom section of the water heater It is on short circuit S1 Frost On turning on the power the temperature of th...

Страница 11: ...oleness before turning it on again S5 E1 A breakdown in the water heater s middle temperature sensor It is broken or disconnected S5 E2 A breakdown in the water heater s middle temperature sensor It i...

Страница 12: ...r Changing the set temperature Further pressing any of the same buttons changes the set temperature in the relevant direction The View Enter button saves the new settings and the screen goes back to i...

Страница 13: ...the changes made on the current parameter Setting menus appear in the following order 1 Setting the temperature for turning on and off the electrical heater if it has been activated It turns on when t...

Страница 14: ...terval when the pump can turn on to transfer the heat energy to the solar collector on Holiday mode This interval must be during the night for this mode to make sense 9 Turns on off the anti frost saf...

Страница 15: ...stem Settings If you still have no boiler or solar installations you can deactivate them Moreover if you don t want the water heater to use electricity for the electrical heater you can disable it too...

Страница 16: ...reen view is in Design I press and hold for more than 2 seconds the F button to enter Settings mode menu Clear Errors By pressing the button select line Yes and press F again to save your choice and g...

Страница 17: ...ter heater s initial settings The temperature regulators NHC H42 are designed for different types of water heaters The necessary personalization is not made in the factory and after you instal your wa...

Страница 18: ...s to the next field of the same parameter by pressing button and it will start blinking increase the value of the blinking field by pressing the button and decrease it by pressing the button pressing...

Отзывы: