solar installation's circulation pump works constantly to avoid overheating of the
solar collector!!!
■
S3 Frost
– The collector's temperature sensor has registered temperature lower than
the set critical minimum temperature and it is possible the fluid to be frozen. Only
modes with electrical heating and boiler heating will work. Must check the system
wholeness, before turning it on again.
■
S4 E1
– A breakdown in the boiler's temperature sensor. It is broken or disconnected.
Only modes with electrical heating and solar heating will work.
■
S4 E2
– A breakdown in the boiler's temperature sensor. It is on short circuit. Only
modes with electrical heating and solar heating will work.
■
S4 Frost
– The boiler's temperature sensor has registered temperature lower than the
set critical minimum temperature and it is possible the fluid to be frozen. Only modes
with electrical heating and solar heating will work. Must check the system wholeness
before turning it on again.
■
S5 E1
– A breakdown in the water heater's middle temperature sensor. It is broken or
disconnected.
■
S5 E2
– A breakdown in the water heater's middle temperature sensor. It is on short
circuit.
■
S5 Frost
– On turning on the power supply the temperature of the water in the water
heater is below zero and it is possible to be frozen. Must check the wholeness of the
tank before turning the power supply on again.
** diagrams for the consumed electricity and pumps performance
A diagram for the consumed electricity, divided by hours for the
current day. 50% for one hour means that the electrical heater
has been working on its full power for 30 minutes out of 60
possible.
A diagram for the active hours of the solar collector's circulation
pump, divided by hours for the current day. 50% for one hour
means that the pump has been working for 30 minutes out of 60
possible.
A diagram for the active hours of the boiler's circulation pump,
divided by hours for the current day. 50% for one hour means
that the pump has been working for 30 minutes out of 60
possible.