background image

www.naturalchoicewater.com 

ION TS Series Owners Manual 

9

g

uideLines

Use the following guidelines to help ensure a proper ION installation:

 

DO NOT use tubing with less than a 180 PSI (13 BAR) rating.

 

If using adapter fitting from 3/4 inch GHT (USA/CAN) or BSP (Export 

Models) to 1/4 inch line, do not connect copper line directly to push-

to-connect fitting.  If building code or regulations require copper 

tubing, contact Natural Choice Technical Support for connection 

recommendations.

 

Make sure there are no sharp bends or kinks in the tubing. Allow extra 

tubing to prevent stress on the fittings. Avoid tubing contact with other 

objects and sharp edges.

 

All tubing used in the elbow fitting and shutoff valve must be clean, cut 

square with a sharp knife or razor, and free of nicks and burrs.

 

If you need additional tubing, make sure it is 1/4 inch OD and meets 

ANSI/NSF and FDA standards for drinking water. DO NOT use tubing 

of an unknown quality or origin.

i

nstaLLation

!

CAUTION:

 Risk of electric shock and damage to interior walls or leak and/or 

flood if improperly installed.

Step 1:  Connect the Plumbing

     

Method 1: Braided Hose with 3/4 inch GHT or BSP Fitting (Export).

1.  Firmly tighten the hose to the back of the ION, and connect to the water 

supply.

2.  Check for water leaks at connection points.

Garden Hose

Thread

Содержание ION TS Series

Страница 1: ...TS Series Drinking Water Appliance Owners Manual...

Страница 2: ...www naturalchoicewater com Package Contents 2 Owner s Manual Power Cord Water Supply Installation Kit Order Part 8606 Adapter Fitting Elbow Fitting Shutoff Valve 10 ft 3 m Blue Tubing...

Страница 3: ...feguards 5 6 Getting to Know the ION 7 Installation Requirements 8 Installation Procedure 9 15 Service Information 16 Touch Screen Operation 17 Learning about SleepMode 18 Filter Replacement 19 20 Mai...

Страница 4: ...ase contact us with your questions at 1 800 547 7726 internationally at 1 815 874 4444 Unpacking the unit WARNING Plastic bags present a choking hazard Keep away from children Product Registration Reg...

Страница 5: ...s the drip tray or faucet Do not operate any ION with a damaged cord or plug Additionally if the ION has malfunctioned or been dropped or damaged in any manner return the ION to your authorized Natura...

Страница 6: ...a long extension cord is used the marked electrical rating of the extension cord must be at least as great as the electrical rating of the ION Also the longer cord should be arranged so that it does n...

Страница 7: ...w the ION Torx 20 Wrench Filter Door ION Filter Faucet Drip Tray and Cover removable Touch Screen Faucet Cover USB Port Tube Removal Tool Model Options The following table lists available models and t...

Страница 8: ...ape may be required to make the connection under the sink at the water supply In the event service is required on the ION locate the Torx 20 wrench behind the filter door to remove panel screws See ph...

Страница 9: ...ubing to prevent stress on the fittings Avoid tubing contact with other objects and sharp edges All tubing used in the elbow fitting and shutoff valve must be clean cut square with a sharp knife or ra...

Страница 10: ...ly push the other end of the tubing into the Elbow Fitting Thread the adapter fitting onto the H2O inlet and tighten firmly The stem of the Elbow Fitting is then pushed into the adapter fitting 3 Turn...

Страница 11: ...is filled with water could result in permanent damage to the ION 1 Connect the female end of the power supply cord to the back of the ION 2 Plug the other end of the power supply cord into a grounded...

Страница 12: ...water flowing inside the ION This is normal DO NOT leave ION unattended during Fill sequence Also periodically check to make sure no leaks are present 1 Select Language and proceed to next screen 2 E...

Страница 13: ...ing Water System allow up to five minutes Set Up Complete All Models All screens will change to Set Up Complete when finished filling Please allow 1 2 hours for ideal temperatures to be reached Hot Wa...

Страница 14: ...back in to the Internal Carbonation Tank to allow for proper mixing of CO2 gas and water Ensure that the CO2 Regulator pressure is always set to 60 PSI 4 BAR Sparkling Water Installation The type of C...

Страница 15: ...ing button until only CO2 dispenses 7 Turn water supply shutoff valve to ON position 8 Water will fill the Internal Carbonation Tank to allow for proper mixing of CO2 gas and water Sparkling Water Ins...

Страница 16: ...when you call our Technical Service Department at 1 800 547 7726 internationally at 1 815 874 4444 These numbers are located on the ION as shown below Serial number Model number 200 XXXXXXXX Find tro...

Страница 17: ...se the button For Settings Screen locate the three circles at the top left of the Touch Screen and press Hot Safety Screen All Hot Water models include a hot safety feature You will be directed to a s...

Страница 18: ...ure This reduces the amount of energy consumed This feature is programmed OFF on all new ION appliances To enable access the Settings menu and select SleepMode Toggle the gray OFF button to green ON Y...

Страница 19: ...contact Customer Service at 1 800 547 7726 internationally at 1 815 874 4444 or visit our website at www naturalchoicewater com ION Water Filtration Options TIP Before you start you may want to have...

Страница 20: ...Flush carbon dust and air from filter by pressing and holding the Ambient dispensing button until water runs clear 2 3 gallons 7 11 liters may be necessary 5 Go to the Settings Menu of the Touch Scree...

Страница 21: ...p Tray has been emptied A friendly reminder will also display to clean the Faucet and Drip Tray periodically to keep your ION looking like new NOTE DO NOT use chemical or abrasive cleaners as they may...

Страница 22: ...of maintaining your ION This message will not cause the ION to shutdown CAUTION Failure to clean the fan could result in temperature loss or mechanical failure or damage The following illustration is...

Страница 23: ...would affect the performance of the ION All ION Appliances arrive with the Passcode Lock Screen unlocked To enable access the Settings menu and select Advanced In the Advanced screen press Passcode Al...

Страница 24: ...he error If error continues to occur during initial start up please contact Technical Support for further assistance 3 Carbonation Tank If the carbonation tank level sensor does not detect water after...

Страница 25: ...re storing If possible allow 24 hours for ice in Ice Tank to melt before draining Contact Natural Choice for more detailed instructions on draining the ION WARNING Water draining from the Hot Tank may...

Страница 26: ...If you need further assistance call us at 1 800 547 7726 internationally at 1 815 874 4444 and our trained Technical Support team will help you resolve the issue over the phone When you call please b...

Страница 27: ...as described in the literature enclosed with the product i e replacing filters cleaning fans etc Neglect improper maintenance abuse modification or alteration of the product will invalidate this warr...

Страница 28: ...ending U S and International Patents Natural Choice Corporation 1990 2017 All Rights Reserved NCC9127 09 50909 Natural Choice Corporation 5677 Sockness Drive Rockford Illinois 61109 USA 800 547 7726 8...

Отзывы: