Specifications
This appendix lists the RMC-8357 electrical, mechanical, and environmental specifications.
Electrical
AC Input
Input voltage range
100 to 240 VAC
Operating voltage range
90 to 264 VAC
Input frequency
50/60 Hz
Operating frequency range
47 to 63 Hz
Current rating
12 to 6 A max (750 W max single power supply)
Power disconnect
The AC power cable provides main power
disconnect. Depressing the front panel power
switch enables or inhibits the internal power
supply.
DC Input
Input
23 V to 36 V, 16 A to 8 A ±10%
Current rating
+12 V -41 A
+5 VSB 0 to 3 A
DC output
500 W (max)
Note
The connection to a DC mains supply is considered an energy hazard and
must not be in an operator access area. The DC product must be located in a
Restricted Access Location.
Caution
Use the DC power cable provided with DC power supplies for VDC input.
Caution
Using the RMC-8357 in a manner not described in this document may
impair the protection the RMC-8357 provides.