![background image](http://html1.mh-extra.com/html/national-instruments/ni-dids-2103/ni-dids-2103_user-manual_3423830006.webp)
6 | ni.com | NI DIDS-2100 Series User Manual
2.1 REVERSE BATTERY POLARITY WARNING
NI Powertrain Controls power modules are not internally protected against reverse battery polarity.
Do not reverse the battery polarity or damage will occur. This event is not covered under warranty.
All NI Powertrain Controls modules with a 10-pin screw terminal block have identical external
power and ground connections. Please take necessary precautions to ensure that BATT (0)
and GND (9) are not connected in reverse polarity. The BATT (0) terminal will accept positive
7-32VDC with respect to the GND (9) terminal. Please refer to the user manual for details.
To provide system-level protection against reverse battery polarity, implement the following simple external
main-power-relay circuit:
Figure 2.1.a, Reverse Battery Protection Diagram
Notes:
1.) The relay shown is a type of automotive relay which includes an internal series diode with terminal 85. This diode
will prevent reverse battery from energizing the relay.
2.) Terminals 30 and 87 are screw terminals and should be connected with soldered ring terminals.
3.) Terminals 85 and 86 are 0.250 X 0.031 inch (6.3 X 0.8 mm) push-on terminals.
4.) A fuse is recommended between the battery and relay.
5.) An optional switch may be placed in series with relay terminal 86.
6.) Simply placing a high-current-capacity diode in series with the system power is not an acceptable method
of reverse battery protection because it will not allow the NI Powertrain Controls modules to perform current
recirculation while switching inductive loads.
7.) The relay is currently available from
Содержание NI DIDS-2103
Страница 11: ...NI DIDS 2100 Series User Manual National Instruments 11 3 2 Software...
Страница 32: ...32 ni com NI DIDS 2100 Series User Manual...
Страница 40: ...40 ni com NI DIDS 2100 Series User Manual 3 3 Hardware...
Страница 44: ...44 ni com NI DIDS 2100 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Страница 174: ...174 ni com NI DIDS 2100 Series User Manual Aux PWX 2 4 See above descriptions...
Страница 208: ...208 ni com NI DIDS 2100 Series User Manual 10 Connecting Solenoid Direct Injectors to the DI Driver...
Страница 209: ...NI DIDS 2100 Series User Manual National Instruments 209 11 Connecting Piezo Direct Injectors to the DI Driver...
Страница 210: ...210 ni com NI DIDS 2100 Series User Manual 12 Connecting Port Fuel Injectors to the PFI Driver...
Страница 212: ...212 ni com NI DIDS 2100 Series User Manual 14 Connecting General Purpose Solenoids to the PFI Driver LS Channels...
Страница 213: ...NI DIDS 2100 Series User Manual National Instruments 213 15 NI 9411 to Single Ended and Differential Encoder...
Страница 214: ...214 ni com NI DIDS 2100 Series User Manual 16 9066 RS 232 Serial Connector to TDK Power Supply...
Страница 216: ...216 ni com NI DIDS 2100 Series User Manual 8 Important Information...
Страница 223: ...NI DIDS 2100 Series User Manual National Instruments 223...