NI DIDS-2100 Series User Manual | © National Instruments | 159
4.11 Rail Pressure Control Setup Window
The purpose of the Rail Pressure Control (RPC) Setup window, is to configure a dedicated direct injection common-
rail fuel pressure control function. The function writes to the optional PFI Driver module lowside driver channels
which are connected to a high pressure pump Inlet Metering Valve (IMV) and a High Pressure Valve (HPV) on the
rail. The RPC function implements two PID controllers; one for RPC via the IMV, and one for RPC via the HPV. Only
one PID controller may be enabled at one time, either for IMV PID or HPV PID. While IMV PID is enabled, the HPV
must be controlled via constant PWM duty cycle. While HPV PID is enabled, the IMV must be controlled via constant
PWM duty cycle. The reason for this is because two PID controllers acting on IMV and HPV simultaneously would
conflict. Typically, RPC is performed using IMV PID control while applying a constant duty cycle to the HPV. The
RPC function must also have rail pressure feedback from an analog sensor mounted to the fuel rail. The analog
signal can be connected to any of the four channels of the optional NI 9201 analog input module. The utilized analog
channel can be selected via this Rail Pressure Control Setup window.
Typical IMV and HPV solenoids require up to 3A continuous current operation. Therefore it is important to utilize the
feature which locks LS1 with LS2 and locks LS3 with LS4. The locked channel pairs can be used
to operate the IMV and HPV with up to 3A continuous current. The example wiring diagram, figure 4.10.a, illustrates
wiring an IMV to a locked LS1 and LS2 pair, and wiring a HPV to a locked LS3 and LS4 pair. The LS channel locking
feature can be implemented via the
Содержание NI DIDS-2103
Страница 11: ...NI DIDS 2100 Series User Manual National Instruments 11 3 2 Software...
Страница 32: ...32 ni com NI DIDS 2100 Series User Manual...
Страница 40: ...40 ni com NI DIDS 2100 Series User Manual 3 3 Hardware...
Страница 44: ...44 ni com NI DIDS 2100 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Страница 174: ...174 ni com NI DIDS 2100 Series User Manual Aux PWX 2 4 See above descriptions...
Страница 208: ...208 ni com NI DIDS 2100 Series User Manual 10 Connecting Solenoid Direct Injectors to the DI Driver...
Страница 209: ...NI DIDS 2100 Series User Manual National Instruments 209 11 Connecting Piezo Direct Injectors to the DI Driver...
Страница 210: ...210 ni com NI DIDS 2100 Series User Manual 12 Connecting Port Fuel Injectors to the PFI Driver...
Страница 212: ...212 ni com NI DIDS 2100 Series User Manual 14 Connecting General Purpose Solenoids to the PFI Driver LS Channels...
Страница 213: ...NI DIDS 2100 Series User Manual National Instruments 213 15 NI 9411 to Single Ended and Differential Encoder...
Страница 214: ...214 ni com NI DIDS 2100 Series User Manual 16 9066 RS 232 Serial Connector to TDK Power Supply...
Страница 216: ...216 ni com NI DIDS 2100 Series User Manual 8 Important Information...
Страница 223: ...NI DIDS 2100 Series User Manual National Instruments 223...