![National Instruments NI cDAQ-9181 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/national-instruments/ni-cdaq-9181/ni-cdaq-9181_user-manual_3435125032.webp)
© National Instruments
|
1-23
NI cDAQ-9181/9184/9188/9191 User Manual
•
Panel Mounting without a Panel Mount Kit
—You can mount the cDAQ chassis directly
on a flat surface using the mounting holes. Align the chassis on the surface. Then, fasten
the chassis to the surface using two screws as shown in Figure 1-16. The cDAQ-9184 uses
two M4 or No. 8 flathead screws. The cDAQ-9188 uses two M4 or No. 8 panhead screws.
National Instruments does
not
provide these screws with the chassis.
Figure 1-16.
Mounting the cDAQ Chassis Directly on a Flat Surface
Refer to the specifications document for your cDAQ chassis for mounting dimensions.
Caution
Make sure that no modules are in the chassis before removing it from the
surface.
Mounting the cDAQ Chassis on a DIN Rail
Caution
To maintain product performance and accuracy specifications when the
ambient temperature is between 45 °C and 55 °C, you must mount the chassis to a
metal panel or surface using the screw holes or the panel mount kit. DIN mounting
limits the device to 45 °C maximum ambient operating temperature. Measure the
ambient temperature at each side of the CompactDAQ system 63.5 mm (2.5 in.) from
the side and 25.4 mm (1 in.) from the rear cover of the system. For further
information about mounting configurations, go to
and enter the Info
Code
cdaqmounting
.
You can use a DIN rail kit to mount the cDAQ chassis to a standard DIN rail. For kit accessory
ordering information, refer to the pricing section of your cDAQ chassis product page at
NI cDAQ-9184
NI CompactDAQ