1.
Use a Phillips head screwdriver to remove the two screws holding the battery cover plate.
Remove the plate, then remove battery from the device.
2.
Insert a new battery in the device. Ensure the positive terminal of the battery faces
outward. Refer to the device specifications for the required battery type.
3.
Replace the battery cover plate.
Replacing the battery resets the BIOS settings to their default values.
Increasing the Battery Life
When storing the controller, you can disconnect the battery to deactivate the real-time clock
and reset the BIOS settings to their default values. Take the following steps to disconnect the
battery:
Caution
Before removing the battery cover, disconnect all power connectors and
I/O cables from the device. To prevent damage from electrostatic discharge (ESD),
ground the unit and yourself by using a grounding strap or touching a grounded
object, such as a computer chassis.
1.
Use a Phillips head screwdriver to remove the two screws holding the battery cover plate.
Remove the plate.
2.
Locate the BATTERY CONNECT switch above the battery and move the switch toward
the front panel of the device. The battery is now disconnected from the device.
3.
Replace the battery cover plate.
20
|
ni.com
|
IC-317x User Manual