Chapter 5
S Mode Functions
© National Instruments Corp.
5-29
GPIB-SCSI-A User Manual
config
(continued)
Example:
Request the GPIB-SCSI-A to return to the Initiator the five bytes of
parameter identification. The buffering method used is Single
Buffering, and the buffer size is set to 32K. The Parallel Poll subset
used by the GPIB-SCSI-A is set to PP1.
Build SCSI Command Descriptor Block (CDB)
Byte 0 = 0xDE
Byte 1 = 0x02
Byte 2 = 0x80
Byte 3 = 0x00
Byte 4 = 0x05
Byte 5 = 0x00
SCSIArbitrate
SCSISelect(GPIB-SCSI-A id)
SCSICmd(CDB)
SCSIRead(configinfo,5)
SCSIStatus(Sbyte)
SCSIMesgIn(Mbyte)
ErrorCheck