Troubleshooting Device Connectivity
If your FieldDAQ device becomes disconnected from the network, open MAX and try the
following:
•
After moving the device to a new network, NI-DAQmx may lose connection to the
device. In this case, click
Reconnect
to provide NI-DAQmx with the new hostname or IP
address.
•
The FieldDAQ device icon indicates whether it is recognized and present on the network.
If a connected device appears as disconnected in the configuration tree in MAX, select
Self-Test
or
Reset
. If successful, the device icon changes to dark grey.
Figure 27. MAX Icons and States
2
1
3
1. Discovered, but Not Added to the Network
2. Recognized, Present, and Reserved on the Network
3. Recognized, but Disconnected from the Network, Unreserved, or Reserved by Another Host
For additional troubleshooting resources for the FieldDAQ device, refer to the
Finding a
Network DAQ Device in MAX
topic in the
Measurement & Automation Explorer Help for
NI-DAQmx
.
Reserving the Device in MAX
When the FieldDAQ device is connected to a network, multiple users can access the device.
To perform any DAQ functionality on the device, including reset and self-test, you must
reserve the device in MAX. In MAX, an unreserved device or device reserved by another host
appears with an X and a reserved device appears as dark grey. Only one user at a time can
reserve the FieldDAQ device.
If the device was not reserved automatically after it was added (
Add Device
), you can reserve
the device in MAX by expanding
Devices and Interfaces
»
Network Devices
, selecting the
device, and clicking the
Reserve Network Device
button. The Override Reservation dialog
box opens when you attempt to explicitly reserve a device. Agreeing to override the
reservation forces the FieldDAQ device to be reserved by the current user.
STATUS LED
The FieldDAQ device has a STATUS LED.