Figure 10. FD-11634 Pinout
AI–
NC
NC
AI+
NC
2
3
4
5
1
Table 5. Signal Descriptions
Pin Number
Wire Color*
Signal
Description
1
3
5
Brown
Blue
Gray
NC
No connect. Do not connect signals to
this terminal.
2
White
AI-
Negative analog input signal and
TEDS return
4
Black
AI+
Positive analog input signal and
TEDS data
* Wire color pertains to SHM125M I/O cables sold through NI. Other manufacturers' cable
wire colors may vary.
Note
M12 connectors must be mated to cables or have caps installed on them to
meet IP65/IP67 requirements. Cover the unused connectors with the included plastic
caps whenever water, dust, or dirt are present.
M12-BNC Cabling
You can use the SHM125M-BNCF and SHM125M-BNCF-RA cables with the FD-11634. The
following figure shows the pinouts for the M12 and BNC connector on the cables.
Figure 11. SHM125M-BNCF and SHM125M-BNCF-RA Cable Pinout
AI+
AI–
NC
AI–
AI+
NC
NC
2
3
4
5
1
BNC
M12
16
|
ni.com
|
FD-11634 User Guide
Содержание FD-11634