Replacing RMX Power Supplies
(ECUTS-16000) Replacing RMX Power Supplies
Equipment
•
#2 Phillips screwdriver
•
Flathead screwdriver
1.
Power off the ECUTS-16000.
2.
Remove the four screws from each filler panel above the mass interconnect using the #2 Phillips screwdriver.
3.
Remove the filler panels above the mass interconnect.
4.
Using the flathead screwdriver, turn the two quarter turn locks on each side panel of the test rack.
5.
Remove each side panel of the test rack.
6.
Turn off the power switch on the front of each of the RMX power supplies.
7.
Disconnect the power ring terminal connectors from the rear of the RMX power supplies.
8.
Disconnect the sense connector from the rear of the RMX power supplies.
9.
Disconnect the interlock connector from the rear of the RMX power supplies.
10. Disconnect the ethernet jack from the rear of the RMX power supplies.
11. Disconnect the AC power cable from the rear of RMX power supplies.
12. Remove the four screws securing the RMX power supply tray to the test rack using the #2 Phillips screwdriver.
13. Slide the RMX power supply tray out of the left side of the test rack.
14. Remove the three screws securing the RMX power supply to the tray using the #2 Phillips screwdriver.
15. Screw in the three screws on the tray to the replacement RMX power supply using the #2 Phillips screwdriver.
16. Slide the RMX power supply tray back into the left side of the test rack.
17. Screw in the four screws holding the RMX power supply to the test rack using the #2 Phillips screwdriver.
18. Connect the AC power cable to the RMX power supplies.
19. Connect the ethernet jack from the rear of RMX power supplies.
20. Connect the interlock connector from the rear of RMX power supplies.
21. Connect the sense connector from the rear of RMX power supplies.
22. Connect the power ting terminal connectors to the rear of the RMX power supplies.
23. Turn on the power switch on the front of all the RMX power supply.
24. Tighten the screws securing the mass interconnect to the test rack using the #2 Phillips screwdriver.
25. Replace each filler panel above the mass interconnect.
26. Screw in the four filler panel screws on each filler panel using the #2 Phillips screwdriver.
Configuration Steps
27. Reset the RMX power supply to the default factory settings.
a)
Flip the power switch to the on position.
b)
Press the MENU button to illuminate the menu LED and wait for
SEt
to appear on the voltage display.
c)
Turn the voltage encoder until
MEMO
appears.
d)
Press the voltage encoder and wait for
SAVE
to appear.
e)
Turn the voltage encoder until
F.rst
appears.
f)
Press the voltage encoder and wait for
F.rst
to appear on the voltage display and
YES
to appear on the current display.
g)
Press the current encoder and wait for
HOLD
to appear.
h)
Press the MENU button twice to turn the menu LED off.
28. Configure the power supply IP address.
a)
Press the REM button on the front panel of the power supply.
b)
Press the current encoder and wait for
Adr
to appear on the current display.
c)
Turn the current encoder to address
6
.
d)
Press the current encoder to save the address.
29. Reset the power supply to the LAN default factory settings.
a)
Press the REM button on the remote.
b)
Turn the voltage encoder until
rST
appears on the voltage display.
c)
Press the current encoder and wait for
rST
to appear on the current display.
d)
Press the current encoder to reset the system.
e)
Flip the power switch to the off position and leave the RMX-410 power supply off for five seconds.
f)
Flip the power switch to the on position.
ECUTS-16000/16001 User Manual
|
© National Instruments Corporation
|
55