Tip
MAX lists the system under the model number followed by the
serial number, such as NI-cRIO-9063-1856AAA.
Configuring Startup Options
Complete the following steps to configure the cRIO-9063 startup options in MAX.
1. In MAX, expand your system under Remote Systems.
2. Select the
Startup Settings
tab to configure the startup settings.
cRIO-9063 Startup Options
You can configure the following cRIO-9063 startup options.
Table 1.
cRIO-9063 Startup Options
Startup
Option
Description
Force Safe
Mode
Rebooting the cRIO-9063 with this setting on starts the cRIO-9063 without
launching LabVIEW Real-Time or any startup applications. In safe mode, the
cRIO-9063 launches only the services necessary for updating configuration and
installing software.
Enable
Console Out
Rebooting the cRIO-9063 with this setting on redirects the console output to the
RS-232 serial port. You can use a serial-port terminal program to read the IP
address and firmware version of the cRIO-9063. Use a null-modem cable to
connect the RS-232 serial port to a computer. Make sure that the serial-port
terminal program is configured to the following settings:
■
115,200 bits per second
■
Eight data bits
■
No parity
■
One stop bit
■
No flow control
Disable RT
Startup App
Rebooting the cRIO-9063 with this setting on prevents any LabVIEW startup
applications from running.
Disable FPGA
Startup App
Rebooting the cRIO-9063 with this setting on prevents autoloading of any FPGA
application.
© National Instruments
5
cRIO-9063 Features
Содержание cRIO-9063
Страница 1: ...cRIO 9063 Features 2022 06 30...