LED Pattern
Indication
This pattern may also indicate that the user has forced the cRIO-9066 to boot
into safe mode by pressing the reset button for longer than five seconds or
by enabling safe mode in MAX. Refer to the Measurement & Automation
Explorer (MAX) Help for information about safe mode.
Blinks four times
and pauses
The cRIO-9066 is in safe mode. The software has crashed twice without
rebooting or cycling power between crashes.
Continuously
blinks
The cRIO-9066 has not booted into NI Linux Real-Time. The cRIO-9066 either
booted into an unsupported operating system, was interrupted during the
boot process, or detected an unrecoverable software error.
On momentarily
The cRIO-9066 is booting. No action required.
Off
The cRIO-9066 is in run mode. Software is installed and the operating system
is running.